logo
good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Vector Network Analyzer
Created with Pixso. 10 MHz to 20 GHz 2 Port Vector Network Analyzer with 121 dB Dynamic Range VNA

10 MHz to 20 GHz 2 Port Vector Network Analyzer with 121 dB Dynamic Range VNA

Brand Name: Agilent / Keysight
Model Number: E8362B
MOQ: 1 Piece
Price: USD 18000-26000 / Piece
Delivery Time: 3-7 working days for stock, 15-25 days for bulk order
Payment Terms: T/T,L/C,Western Union
Detail Information
Place of Origin:
Guangdong, China
Certification:
CE, IEC/EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1
Model:
Agilent E8362B
Series:
Agilent / Keysight PNA Series Microwave Network Analyzers
Type:
Vector Network Analyzer (VNA)
Frequency Range:
10 MHz To 20 GHz
Test Ports:
2 Ports, 3.5 Mm Male, 50 Ohm
Receivers:
4 (A, B, R1, R2)
System Dynamic Range:
117 DB (0.5-2 GHz), 120 DB (2-10 GHz), 121 DB (10-20 GHz)
Receiver Dynamic Range:
119 DB (0.5-2 GHz), 122 DB (2-10 GHz), 125 DB (10-20 GHz)
Test Port Noise Floor:
< -114 DBm (10 Hz IFBW, 0.5-2 GHz), < -120 DBm (10-20 GHz)
Trace Noise Magnitude:
< 0.006 DB Rms At 1 KHz IFBW
Trace Noise Phase:
< 0.060 Deg Rms At 1 KHz IFBW
Frequency Resolution:
1 Hz
CW Accuracy:
+/- 1 Ppm
Nominal Output Power:
0 DBm Standard
Power Range:
-25 To +5 DBm (45 MHz-10 GHz), -24 To +3 DBm (10-20 GHz)
Power Level Accuracy:
+/- 1.5 DB (45 MHz-10 GHz), +/- 2.0 DB (10-20 GHz)
Power Resolution:
0.01 DB
Third Order Intercept:
+24 DBm Typical (0.5-20 GHz)
Phase Noise:
-60 DBc At 1 KHz Offset (10 MHz-10 GHz), -55 DBc (10-20 GHz)
IF Bandwidth Range:
1 Hz To 40 KHz
Measurement Channels:
32 Independent Channels
Points Per Sweep:
2 To 16,001
Display:
8.4 In Colour LCD, 640 X 480
CPU:
Intel 1.1 GHz Pentium M, 1 GB RAM
Interfaces:
GPIB IEEE 488.2, LAN 10Base-T, USB, SICL/LAN, DCOM
Calibration Types:
Full 2-port, 1-port, Response And Isolation, TRL/TRM, Scalar And Vector Mixer
Supported Options:
010 Time Domain, 014 Configurable Test Set, UNL Extended Power Range And Bias Tees, 080 Frequency Offset, 081 Reference Channel Switch, 082 Scalar Converter, 083 Frequency Converter, H08 Pulsed, H11 External IF Inputs
Line Power:
100-240 V, 50/60/400 Hz, 350 W Max
Dimensions:
267 X 426 X 427 Mm
Weight:
29 Kg Net, 36 Kg Shipping
Operating Temperature:
0 C To +40 C
Storage Temperature:
-40 C To +70 C
Safety:
IEC/EN 61010-1, UL 61010-1, CSA C22.2 No. 61010-1
Warranty:
Per Manufacturer, Extended Warranty Available
Packaging Details:
Factory foam-lined instrument carton with front panel protection, export-grade double-wall corrugated crate
Supply Ability:
15 Pieces per Month
Highlight:

121 dB Dynamic Range 3.5 mm

,

Four Receiver PNA Architecture

,

0.006 dB rms Trace Noise

Product Description
Product Overview

The Agilent (now Keysight) E8362B is a 2-port PNA Series microwave vector network analyzer covering 10 MHz to 20 GHz with 3.5 mm test ports. It belongs to the four-receiver PNA microwave family that also includes the E8363B (40 GHz), E8364B (50 GHz) and E8361A (67 GHz), sharing the same firmware, calibration engine and user interface.

With 121 dB system dynamic range in the 10 to 20 GHz band and typical trace noise below 0.006 dB rms, the E8362B resolves deep stop-band rejection, high-Q filter skirts and low-level spurious responses that simpler analyzers miss. The four-receiver architecture (A, B, R1 and R2) supports true TRL and TRM calibration for on-wafer, in-fixture and waveguide environments, while the configurable test set and extended power range options allow the instrument to be tailored for active device measurement.

Key Features
  • 10 MHz to 20 GHz, 2-port: covers microwave component test from HF up to K band, with 3.5 mm male 50 Ω test ports.
  • 121 dB system dynamic range in the 10 to 20 GHz band, 120 dB from 2 to 10 GHz and 117 dB from 500 MHz to 2 GHz.
  • Low trace noise: less than 0.006 dB rms magnitude and 0.060° rms phase at 1 kHz IF bandwidth across 500 MHz to 20 GHz.
  • Four receiver architecture (A, B, R1, R2): full S11, S21, S12, S22 plus arbitrary receiver ratio measurements such as A/R1, B/R2 and R1/R2.
  • Complete calibration suite: full two-port, one-port, response and isolation, frequency response, TRL/TRM and scalar or vector mixer calibration, plus interpolated error correction.
  • Wide IF bandwidth range: 1 Hz to 40 kHz, allowing a direct trade of sweep speed against noise floor.
  • Fast setup depth: 32 independent measurement channels, up to 16 display windows, four active traces plus four memory traces per window, and 10 markers per trace.
  • Comprehensive formats: log and linear magnitude, SWR, phase, group delay, real and imaginary, Smith chart and polar.
  • Segment sweep: independent power level, IF bandwidth and sweep time per segment, up to 16,001 points per sweep.
  • Source power control: 0 dBm nominal output on the E8362B, with a 60 dB internal attenuator range and power slope in dBm/GHz.
  • Automation ready: GPIB to IEEE 488.2 and SCPI, LAN control over 10Base-T, SICL/LAN, DCOM, and internal COM applications in VB, VC++, VEE or LabVIEW.
  • 8.4 inch LCD and hardkey interface: 640 x 480 colour display, front panel hardkeys plus mouse-driven menus, five-language built-in help system.
  • Expandable option set: time domain (010), configurable test set (014), extended power range and bias tees (UNL), frequency offset (080), reference channel switch (081), scalar calibrated converter measurements (082), frequency converter application (083), external IF inputs (H11), pulsed measurement (H08).
Technical Specifications
ModelAgilent E8362B PNA Series microwave network analyzer
Frequency range10 MHz to 20 GHz
Test ports2 ports, 3.5 mm male, 50 Ω
Receivers4 (A, B, R1, R2)
Frequency resolution1 Hz
CW accuracy± 1 ppm
Frequency stability± 1 ppm 0 to 40 °C typical, ± 0.2 ppm/year typical
System dynamic range117 dB (500 MHz to 2 GHz), 120 dB (2 to 10 GHz), 121 dB (10 to 20 GHz)
Receiver dynamic range119 dB (500 MHz to 2 GHz), 122 dB (2 to 10 GHz), 125 dB (10 to 20 GHz)
Test port noise floor (10 Hz IFBW)< -114 dBm (500 MHz to 2 GHz), < -117 dBm (2 to 10 GHz), < -120 dBm (10 to 20 GHz)
Trace noise magnitude< 0.006 dB rms at 1 kHz IFBW (500 MHz to 20 GHz)
Trace noise phase< 0.060° rms at 1 kHz IFBW (500 MHz to 20 GHz)
Nominal output power0 dBm (standard), power range -24 to +3 dB (10 to 20 GHz), -25 to +5 dB (45 MHz to 10 GHz)
Power level accuracy± 1.5 dB (45 MHz to 10 GHz), ± 2.0 dB (10 to 20 GHz)
Power resolution0.01 dB
Third order intercept+24 dBm typical (500 MHz to 20 GHz, 100 kHz to 5 MHz tone spacing)
Phase noise (1 kHz offset)-60 dBc typical (10 MHz to 10 GHz), -55 dBc typical (10 to 20 GHz)
Receiver compression< 0.1 dB at -5 dBm and < 0.45 dB at +5 dBm (10 MHz to 20 GHz)
Damage input level30 dBm or ± 40 VDC at test ports
IF bandwidth range1 Hz to 40 kHz nominal
Display8.4 in diagonal colour active matrix LCD, 640 x 480
Display rangeMagnitude ± 200 dB, phase ± 500°
Display resolution0.001 dB/div magnitude, 0.01°/div phase
Measurement channels32 independent channels
Windows and tracesUp to 16 windows, 4 active plus 4 memory traces per window, 10 markers per trace
Points per sweep2 to 16,001
Sweep typesLinear, CW, power, segment sweep
CPUIntel 1.1 GHz Pentium M, 1 GB RAM
InterfacesGPIB IEEE 488.2, LAN 10Base-T, USB, SICL/LAN, DCOM, COM
Line power100-120 V at 50/60/400 Hz, 220-240 V at 50/60 Hz, auto switching, 350 W maximum
Dimensions267 mm H x 426 mm W x 427 mm D (cabinet, excluding front and rear hardware)
Weight29 kg net, 36 kg shipping, nominal
Operating temperature0 °C to +40 °C
Storage temperature-40 °C to +70 °C
EMCIEC/EN 61326, CISPR 11 Group 1 Class A, AS/NZS CISPR 11, ICES/NMB-001
SafetyIEC/EN 61010-1, CSA C22.2 No. 61010-1, UL 61010-1
Typical Applications
  • S-parameter characterization of microwave filters, couplers, dividers, cables and adapters
  • Amplifier gain, return loss, isolation and 1 dB compression measurements
  • Antenna and waveguide component test up to K band
  • On-wafer, in-fixture and waveguide measurement with TRL/TRM calibration
  • Mixer and frequency converter conversion loss and group delay with Option 080 or 083
  • Time domain fault location and TDR-style reflection analysis with Option 010
  • Production go/no-go testing with limit lines and external triggering
Calibration and Accuracy

Full two-port calibration removes directivity, source match, load match, reflection and transmission tracking plus crosstalk systematic errors. Available calibration types include frequency response, response and isolation, one-port, two-port, TRL/TRM and both scalar and vector mixer calibration, with interpolated error correction over the full frequency range.

Send us your measurement frequency range, device type and calibration kit in use and we will confirm the option configuration, calibration certificate status, lead time and shipping terms.

Agilent Keysight E8362B PNA microwave vector network analyzer front panel with 8.4 inch color LCD display and 3.5 mm test ports
Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

J
J*k
India Aug 13.2026
The item is very well‑packaged. I’m extremely satisfied with it