| Brand Name: | Rohde and Schwarz |
| Model Number: | ZVA67 |
| MOQ: | 1 set |
| Price: | Negotiation |
| Delivery Time: | 1~3 Working Days |
| Payment Terms: | T/T, Western Union, MoneyGram |
| Option Code | Description |
|---|---|
| B-B18 | Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6 |
| B-B18 | Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7 |
| B-B4 | Oven quartz (OCXO) for ZVA, ZVB, ZVT |
| B-K2 | Time domain (for ZVA, ZVB, ZVT) (software license) |
| B-K30 | Noise figure measurement on 2 port devices (for ZVA and ZVT) |
| B16 | Direct generator-receiver-access (for 2 port ZVA67) |
| B21 | Generator Step Attenuator Port 1, mechanical, 50dB in 10dB steps |
| B22 | Generator Step Attenuator Port 2, mechanical, 50dB in 10dB steps |
| B23 | Generator Step Attenuator Port 3, mechanical, 50dB in 10dB steps |
| B24 | Generator Step Attenuator Port 4, mechanical, 50dB in 10dB steps |
| B31 | Receiver Step Attenuator Port 1, mechanical, 35dB in 5dB steps |
| B32 | Receiver Step Attenuator Port 2, mechanical, 35dB in 5dB steps |
| B33 | Receiver Step Attenuator Port 3, mechanical, 35dB in 5dB steps |
| B34 | Receiver Step Attenuator Port 4, mechanical, 35dB in 5dB steps |
| B7 | Measurements on pulsed signals. Pulse profile, Recording time up to 25ms, up to 30MHz bandwidth |
| B8 | External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E |
| C3 | Three years of calibration coverage based on the R&S recommended calibration interval - includes test data |
| C5 | Five years of calibration coverage based on the R&S recommended calibration interval - includes test data |
| DCV-2 | Documentation of calibration values |
| DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
| K10 | Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT |
| K17 | Increases the receiver bandwidth to 5MHz |
| K27 | Two internal pulse generators (for ZVA and ZVT) |
| K4 | Frequency converting measurement for ZVA and ZVT |
| K5 | Phase measurement on mixers (for ZVA, ZVT; ZVA/T-B16 and ZVA-K4 required) |
| K6 | True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports |
| K7 | Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth |
| K8 | Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4) |
| K9 | Measurement of group delay on frequency converters without LO access (for ZVA, ZVT) |
| R3 | Three years of depot repair coverage, including recalibration and test data if necessary to complete a repair |
| R5 | Five years of depot repair coverage, including recalibration and test data if necessary to complete a repair |
| ZV-Z218 | 1.85 mm calibration kit, fixed match, TOSM male and female calibration standards |
| ZV-Z96 | Flexible Precision Cable 50 Ohm 1.85mm(f)Rugged. to 1.85mm(m)Rugged.DUT; DC to 67GHz; 635mm(25 inch); 1 piece |
| ZVAB-B18 | Removable Flash Disc for ZVA/ZVB with controller unit FMR7/3 or FMR7/6 |
| ZVAB-B4 | Oven quartz (OCXO) for ZVA, ZVB, ZVT |
| ZVAB-K2 | Time domain (for ZVA, ZVB, ZVT) |
| ZVAB-K30 | Noise figure measurement on linear and frequency converting 2 port devices (for ZVA, ZBV and ZVT) |