| Brand Name: | Rohde and Schwarz |
| Model Number: | ZVA24 |
| MOQ: | 1 set |
| Price: | Negotiation |
| Payment Terms: | T/T |
With its new R&S ZVA family of vector network analyzers, Rohde & Schwarz takes a future-oriented approach. These analyzers offer a perfect balance between measurement speed, dynamic range, flexibility and precision, making them ideal for present and future measurement tasks.
Building on the success of the R&S ZVR family, the R&S ZVA continues to set standards in RF and microwave measurements. The fundamental mixing concept employed by the receivers ensures high sensitivity and a wide dynamic range, while extremely fast synthesizers enable short measurement times. With excellent characteristics, new functionality, sophisticated GUI and extremely high flexibility, the R&S ZVA is an indispensable tool for demanding measurement tasks in labs and production.
| Option Code | Description |
|---|---|
| B-B18 | Removable Flash Disk 4GB for ZVA/ZVB with control unit FMR6/5 (factory installed only) |
| B-B18 | Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6 |
| B-B18 | Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7 |
| B-B4 | Oven quartz (OCXO) for ZVA, ZVB, ZVT |
| B-K2 | Time domain (for ZVA, ZVB, ZVT) (software license) |
| B-K30 | Noise figure measurement on 2 port devices (for ZVA and ZVT) |
| B16 | Direct generator/receiver access for 2-port ZVA24 |
| B16 | Direct generator/receiver access for 4-port ZVA24 |
| B21 | Generator attenuator port 1, mechanical, 70 dB in 10-dB-steps, 24 GHz |
| B22 | Generator attenuator port 2 mechanical, 70 dB in 10-dB-steps 24 GHz |
| B23 | Generator attenuator port 3 mechanical, 70 dB in 10-dB-steps, 24 GHz |
| B24 | Generator attenuator port 4 mechanical, 70 dB in 10-dB-steps 24 GHz |
| B31 | Receiver attenuator port 1 mechanical, 35 dB in 5-dB-steps 24 GHz |
| B32 | Receiver attenuator port 2 mechanical, 35 dB in 5-dB-steps, 24 GHz |
| B33 | Receiver attenuator port 3, mechanical, 35 dB in 5-dB-steps, 24 GHz |
| B34 | Receiver attenuator port 4 mechanical, 35 dB in 5-dB-steps, 24 GHz |
| B7 | Measurements on pulsed signals. Pulse Profile, Recording time up to 25ms, up to 30MHz bandwidth |
| B7 | Measurements on pulsed signals. Pulse profile, Recording time up to 25ms, up to 30MHz bandwidth |
| B8 | External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E |
| C3 | THREE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY |
| C3 | THREE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY |
| C5 | FIVE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY |
| C5 | FIVE YEARS OF US DEPOT CALIBRATIONS BASED ON R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY |
| DCV-2 | Documentation of calibration values |
| DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
| DKD | ZVA24 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
| K10 | Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT. |
| K17 | Increases the receiver bandwidth to 5MHz (software license) |
| K27 | Two internal pulse generators (for ZVA and ZVT) (software license) |
| K4 | Mixer- and frequency converting measurements for ZVA and ZVT (software license) |
| K5 | Vector corrected mixer measurements (for R&S®ZVA, R&S®ZVT; R&S®ZVA/T-B16 and R&S®ZVA-K4 required) |
| K6 | True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports |
| K7 | Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth |
| K8 | Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4) |
| K9 | Measurement of group delay on frequency converters without LO access (for ZVA, ZVT) |
| R3 | THREE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12 |
| R3 | THREE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12 |
| R5 | FIVE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12 |
| R5 | FIVE YEARS OF DEPOT REPAIR COVERAGE, INCLUDING RECALIBRATION AND TEST DATA IF NECESSARY TO COMPLETE A REPAIR 1ST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE 12 |
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews