logo
good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Mixed Signal Oscilloscope
Created with Pixso. 6 GHz Bandwidth Digital Oscilloscope with 20 GSa/s Sample Rate and 400 Mpts Memory for Mixed Signal Oscilloscope Analysis

6 GHz Bandwidth Digital Oscilloscope with 20 GSa/s Sample Rate and 400 Mpts Memory for Mixed Signal Oscilloscope Analysis

Brand Name: Rohde & Schwarz
Model Number: RTO2064
MOQ: 1 set
Price: Negotiation
Delivery Time: 7-15 days after payment
Payment Terms: T/T
Detail Information
Place of Origin:
Germany
Certification:
CE
Bandwidth:
6 GHz
Channel Number:
4 Analog Channels
Sample Rate:
20 GSa/s, 5 GSa/s All Channels
Acquisition Memory:
Up To 400 Mpts
ADC Resolution:
8 Bit
Display:
12.1 Inch Capacitive Touchscreen
Trigger:
Digital Trigger Unit With Adjustable Hysteresis
Interface:
LAN, USB 3.0, GPIB Optional
Application:
High Speed Digital, Power Integrity And RF Signal Analysis
Packaging Details:
Original foam packaging with test report, mains cable and manual
Supply Ability:
In Stock
Highlight:

Rohde Schwarz RTO2064 oscilloscope

,

6GHz four channel oscilloscope

,

20GSa/s 400Mpts acquisition memory

Product Description
Product Overview

The Rohde & Schwarz RTO2064 is a 6 GHz, four-channel digital oscilloscope from the RTO2000 series, built for engineers who need to see fast edges, rare events and small disturbances within the same acquisition. At 6 GHz, the instrument covers high-speed serial links, fast-switching power stages, radar baseband signals and wideband RF envelopes that a 1 GHz bench scope would simply round off. With 20 GSa/s sampling and up to 400 Mpts of acquisition memory, the scope preserves the time resolution needed to place a cursor on a 50 ps transition while still recording a window long enough to capture the surrounding protocol frame.

The front end is the quiet part of the story. RTO2000-class hardware is known for a low noise floor and a stable trigger, which matters more as bandwidth rises: a wide-open front end also lets more noise in, and a noisy trace hides exactly the small anomalies engineers are hunting. Because the trigger path is separated from the acquisition path, the instrument triggers reliably on narrow pulses and on signals buried slightly below the visible noise band, so a rare glitch appears once rather than never.

Key Features
  • 6 GHz bandwidth on four analog channels: enough headroom for 10 Gbit and faster serial standards, fast-switching converters and wideband modulated signals, without external downconversion.
  • 20 GSa/s sampling: keeps sub-50 ps time resolution on single-shot events, so edge placement and propagation delay between channels remain measurable without averaging.
  • Up to 400 Mpts acquisition memory: long windows can be recorded at full sample rate, which lets protocol traffic and the disturbance inside it stay in one capture.
  • Fast waveform update rate: roughly one million acquisitions per second exposes rare glitches, runt pulses and jitter outliers that a slow scope misses within a few minutes of observation.
  • 12.1-inch capacitive touchscreen: the large display shows four channels plus decoded buses and measurement panels at once, and touch gestures speed up zooming into a suspicious edge.
  • Digital trigger system: a dedicated trigger path with adjustable hysteresis gives stable triggering on narrow pulses and on noisy signals that defeat simple analog trigger comparators.
  • Serial protocol and analysis options: decoding for I2C, SPI, UART, CAN, LIN, FlexRay, USB and Ethernet, plus mask testing, jitter and power integrity analysis packages for deeper investigation.
Technical Specifications
Parameter Specification
ModelRTO2064
Bandwidth6 GHz, 4 analog channels
Sample rateUp to 20 GSa/s, 5 GSa/s on all four channels
Acquisition memoryUp to 400 Mpts
ADC resolution8 bit, high-resolution modes available
Rise timeApproximately 58 ps, calculated
Waveform update rateUp to 1,000,000 waveforms per second
Input impedance50 Ω, BNC input connectors
Display12.1-inch capacitive touchscreen, 1920 x 1080
Trigger systemDigital trigger unit with adjustable hysteresis
InterfacesLAN, USB 3.0, external monitor, GPIB optional
Probes supportedActive and passive probes with automatic identification
Mains supply100 to 240 V AC, 50 / 60 Hz
Operating temperature5 °C to +40 °C
Applications

High-speed digital design is the first use case: validating DDR memory interfaces, PCI Express links, USB 3.x lanes and Ethernet PHYs requires bandwidth plus long memory, because a link that fails once every million frames looks perfectly fine on a short capture. Power integrity work is the second: measuring switching ripple on a 1 V core rail or checking the response of a DC converter to a load step needs a quiet front end and a stable trigger on the transient, not just raw bandwidth.

RF and defence laboratories use the same instrument to examine pulsed envelopes, the rise and fall behaviour of modulated bursts, and timing relationships between baseband control signals and RF output. Production and service departments value it as a shared asset: one four-channel 6 GHz scope covers incoming inspection of high-speed boards, failure analysis of returned units and characterisation of new silicon, while the removable solid-state drive keeps customer data out of the instrument when it moves between benches.

Packaging & Quality Assurance

Each instrument is delivered in original foam packaging with the mains cable, a front cover, the user manual on USB media and a test report recording bandwidth check, channel gain, offset accuracy and trigger sensitivity on all four channels. Units are shipped with a 12-month warranty covering workmanship and materials, and we support firmware updates, probe matching and access to calibration service on request.

Optional accessories such as active probes, high-voltage differential probes and a rack-mount kit are available together with the scope, so the system arrives ready for the first measurement.