| Brand Name: | Hameg |
| Model Number: | HM6050-2 |
| MOQ: | 1 set |
| Price: | Negotiation |
| Delivery Time: | 7-15 days after payment |
| Payment Terms: | T/T |
The HM6050-2 is a professional 50 µH / 50 Ω V-network, also known as a line impedance stabilization network (LISN), built for conducted emission measurements on mains-powered equipment from 9 kHz to 30 MHz. In a conducted emission test setup, the LISN performs two jobs at once: it presents a stable, repeatable radio frequency impedance to the equipment under test, and it filters unwanted noise coming from the public power line so that the measuring receiver only sees interference generated by the device itself. Without a well-defined artificial mains network, measurement results drift from lab to lab and from day to day, which makes compliance decisions unreliable.
The HM6050-2 solves that problem with a passive network that follows the impedance curve defined in CISPR 16-1-2 and EN 55016-1-2: 50 Ω in parallel with a 50 µH inductor plus a 5 Ω series resistor. The unit is housed in a compact aluminium bench case with a clearly marked front panel, phase selection for line, neutral and protective earth, and a 50 Ω measurement output that connects directly to a spectrum analyser, EMI receiver or oscilloscope. Operators can therefore run pre-compliance scans, verify filter designs and confirm production samples without booking a full anechoic chamber slot.
| Parameter | Specification |
|---|---|
| Model | HM6050-2 |
| Network type | V-network (LISN), line to ground |
| Frequency range | 9 kHz – 30 MHz |
| Reference impedance | 50 Ω ∥ (50 µH + 5 Ω) |
| Maximum continuous current | 16 A |
| Maximum operating voltage | 250 V AC, 50 / 60 Hz |
| Measurement output | 50 Ω, N type connector |
| Phase selection | Line, neutral and protective earth |
| Transient limiter | Integrated, switchable |
| Applicable standards | CISPR 16-1-2, EN 55016-1-2, FCC Part 15, ANSI C63.4 |
| Operating temperature | 0 °C to +45 °C |
| Enclosure | Aluminium bench case, shielded |
The network is used wherever engineers need to know how much interference a product injects back into the mains. Typical users include EMC laboratories performing pre-compliance testing before a formal test house visit, design teams verifying that a new EMI filter really attenuates the switching frequency of a converter, and quality departments checking that a mass-produced batch behaves the same as the reference sample. Because the impedance is defined rather than dependent on the local mains installation, results travel well: a scan made in Shenzhen can be compared directly with a scan made in Munich or Detroit.
Practical applications cover switch mode power supplies, LED lighting drivers, variable frequency drives, battery chargers, medical electronics, household appliances, telecom equipment and automotive auxiliary converters. The 16 A rating and 250 V operating voltage fit the majority of single-phase mains-powered products sold worldwide, and the extended low frequency limit of 9 kHz supports the newer harmonic and flicker-related test programmes as well as conventional CISPR 22 and CISPR 32 measurements.
Each HM6050-2 is packed in a foam-lined export carton with the network, a calibrated measurement cable, a grounding strap and an English user manual. Units are individually tested before shipment against a reference network and supplied with a factory calibration report; a 12-month warranty covers workmanship and materials. Spare fuses, replacement transient limiter modules and N type adaptors are available as optional accessories, and our engineers can provide remote guidance on test setup, receiver settings and detector choice during your first conducted emission campaign.