logo
good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
EMC Test System
Created with Pixso. 9kHz-30MHz 16A 50uH 50ohm Line Impedance Stabilization Network LISN V-Network for Conducted Emission EMC Testing

9kHz-30MHz 16A 50uH 50ohm Line Impedance Stabilization Network LISN V-Network for Conducted Emission EMC Testing

Brand Name: Hameg
Model Number: HM6050-2
MOQ: 1 set
Price: Negotiation
Delivery Time: 7-15 days after payment
Payment Terms: T/T
Detail Information
Place of Origin:
Germany
Certification:
CE
Network Type:
V-network LISN
Frequency Range:
9 KHz - 30 MHz
Reference Impedance:
50 Ohm Parallel (50 UH + 5 Ohm)
Max Current:
16 A Continuous
Max Voltage:
250 V AC
Measurement Output:
50 Ohm N Type Connector
Standards:
CISPR 16-1-2, EN 55016-1-2, FCC Part 15
Application:
Conducted Emission Pre-compliance Testing
Packaging Details:
Foam lined export carton with calibration report and manual
Supply Ability:
In Stock
Highlight:

V network LISN 50uH

,

9kHz 30MHz conducted emission

,

CISPR 16-1-2 compliant network

Product Description
Product Overview

The HM6050-2 is a professional 50 µH / 50 Ω V-network, also known as a line impedance stabilization network (LISN), built for conducted emission measurements on mains-powered equipment from 9 kHz to 30 MHz. In a conducted emission test setup, the LISN performs two jobs at once: it presents a stable, repeatable radio frequency impedance to the equipment under test, and it filters unwanted noise coming from the public power line so that the measuring receiver only sees interference generated by the device itself. Without a well-defined artificial mains network, measurement results drift from lab to lab and from day to day, which makes compliance decisions unreliable.

The HM6050-2 solves that problem with a passive network that follows the impedance curve defined in CISPR 16-1-2 and EN 55016-1-2: 50 Ω in parallel with a 50 µH inductor plus a 5 Ω series resistor. The unit is housed in a compact aluminium bench case with a clearly marked front panel, phase selection for line, neutral and protective earth, and a 50 Ω measurement output that connects directly to a spectrum analyser, EMI receiver or oscilloscope. Operators can therefore run pre-compliance scans, verify filter designs and confirm production samples without booking a full anechoic chamber slot.

Key Features
  • Standard V-network impedance: 50 µH + 5 Ω in parallel with 50 Ω, matching the CISPR 16-1-2 reference curve over the whole band, so readings stay comparable with accredited laboratory data.
  • Single unit coverage from 9 kHz to 30 MHz: one instrument serves both the low frequency range used by lighting and motor drives and the shortwave range where switch mode power supplies radiate through the mains cable.
  • 16 A continuous current rating: sufficient for power supplies, LED drivers, inverters, household appliances and small industrial equipment, removing the need for a second high current network.
  • Built-in transient limiter protection: protects the sensitive front end of the measuring receiver against mains spikes and switching surges during unattended automated scans.
  • Low insertion loss and tight impedance tolerance: the passive design keeps measurement uncertainty small and allows repeatable comparison between engineering prototypes and final production units.
  • Rugged aluminium enclosure: shielded housing with star washers and a solid earth stud keeps the reference ground stable and reduces stray coupling inside a busy EMC laboratory.
Technical Specifications
Parameter Specification
Model HM6050-2
Network type V-network (LISN), line to ground
Frequency range 9 kHz – 30 MHz
Reference impedance 50 Ω ∥ (50 µH + 5 Ω)
Maximum continuous current 16 A
Maximum operating voltage 250 V AC, 50 / 60 Hz
Measurement output 50 Ω, N type connector
Phase selection Line, neutral and protective earth
Transient limiter Integrated, switchable
Applicable standards CISPR 16-1-2, EN 55016-1-2, FCC Part 15, ANSI C63.4
Operating temperature 0 °C to +45 °C
Enclosure Aluminium bench case, shielded
Applications

The network is used wherever engineers need to know how much interference a product injects back into the mains. Typical users include EMC laboratories performing pre-compliance testing before a formal test house visit, design teams verifying that a new EMI filter really attenuates the switching frequency of a converter, and quality departments checking that a mass-produced batch behaves the same as the reference sample. Because the impedance is defined rather than dependent on the local mains installation, results travel well: a scan made in Shenzhen can be compared directly with a scan made in Munich or Detroit.

Practical applications cover switch mode power supplies, LED lighting drivers, variable frequency drives, battery chargers, medical electronics, household appliances, telecom equipment and automotive auxiliary converters. The 16 A rating and 250 V operating voltage fit the majority of single-phase mains-powered products sold worldwide, and the extended low frequency limit of 9 kHz supports the newer harmonic and flicker-related test programmes as well as conventional CISPR 22 and CISPR 32 measurements.

Packaging & Quality Assurance

Each HM6050-2 is packed in a foam-lined export carton with the network, a calibrated measurement cable, a grounding strap and an English user manual. Units are individually tested before shipment against a reference network and supplied with a factory calibration report; a 12-month warranty covers workmanship and materials. Spare fuses, replacement transient limiter modules and N type adaptors are available as optional accessories, and our engineers can provide remote guidance on test setup, receiver settings and detector choice during your first conducted emission campaign.