logo
good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
RF Power Meter
Created with Pixso. Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions

Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions

Brand Name: Yokogawa
Model Number: WT332E
MOQ: 1 set
Price: Negotiation
Payment Terms: T/T
Detail Information
Place of Origin:
Japan
Certification:
ISO17025
Product Name:
Power Meter
Current Measurement Range Direct Input:
6 Measuring Ranges/0.5...20 A
Frequency Bandwidth::
DC 0.1 Hz...100 KHz
Condition:
Pre-Owned
Functions:
Tested, In Full Working Conditions
Sampling Rate:
100 KS/s (16 Bit)
Packaging Details:
carton
Supply Ability:
in stock
Highlight:

Yokogawa WT332E power analyzer

,

2 phase digital watt meter

,

tested RF power analyzer

Product Description

Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions

 

Description of Yokogawa WT332E Power Meter

 

2-phase digital Watt meter.
Basic accuracy (50/60 Hz): ±(0.1% from measured power value + 0.05% from RMS measurement range), 6 voltage ranges 15...600 VRMS (Crest factor 3), 6 current ranges 0.5 ARMS...20 ARMS (Crest factor 3). Measurement of VRMS, Vmean, VDC, Vpeak, ARMS, ADC, Apeak, W, VA, var, cos phi, deg, ±Wh, ±Ah, CF, h, Hz and math. functions. Standard with integrator, measurement data memory, max. value memory, filter and frequency counter.
Standard with USB interface, GPIB/IEEE488.2, or RS232C interface (pease select), test certificate.

Features of Yokogawa WT333E Power Meter

 

Benefits of the Yokogawa WT332E 2-phase Digital Watt/Power Meter

  • 2-phase digital watt meter, high accuracy with fast display and data update.
  • Standby measurements according to IEC62301/EN50564, Energy Star and SPECpower.
  • Easy integration into PLC environments with Modbus/TCP (Ethernet).

 

The compact, 2-phase power meters of the WT332E series have a basic accuracy of ±(0.1% of reading + 0.05% of RMS range) and are ideal for precise measurement of power consumption of electrical devices, as well as for energy efficiency and energy saving studies. The lowest currents, for example, can be measured from 50 µA with specified accuracy.

  • Simultaneous harmonic analysis with high bandwidth.
  • Automatic adjustment of the data update rate.
  • Automatic range switching for integrating measurements.
  • Basic accuracy for power measurements (50/60 Hz): ±(0.1% of the measured value + 0.05% of the effective value measuring range).
  • Frequency bandwidth: DC, 0.1 Hz...100 kHz.
  • Current measurement range direct input:6 measuring ranges/0.5...20 A.
  • RMS voltage ranges: 6 measuring ranges/15...600 V.
  • External sensor input EX1: 2.5/5/10 V; EX2: 50/100/200/500 mV/1/2 V.
  • Signals with crest factors up to 300 measurable in all ranges.
  • Simultaneous measurement of RMS, MEAN, and DC voltage.
  • Frequency measurement: 2 channels (voltage and current).
  • 4x 7-segment LED displays
  • Sampling rate 100 kS/s (16 bit).
  • Data update rate 100/250/500 ms/1/2/5/10/20 s, Auto.
  • Harmonics analysis incl. THD calculation up to the 50th order available (option -G5).
  • Automatic range setting in integration mode.
  • Comparator function.
  • Interfaces: USB standard, GPIB/IEEE488 or RS232 (selectable), Ethernet (Modbus/TCP) available (option -C7).
  • Free PC application software WTViewerEfree for parameterization, control and data acquisition included in the scope of delivery.

Options

Option Description
Standard USB
-C1 GPIB/IEEE488 interface Please select one. Only one optionen (-C1 or -C2) can be selected for free.
-C2 RS232C interface
-C7 Ethernet interface incl. Modbus-TCP protocol
-EX1 External sensor input 2.5 V/5 V/10 V Only one can be selected at a time
-EX2 External sensor input 50 mV/100 mV/200 mV/500 mV/1 V/2 V
-G5 Harmonics measurement
-DA12 D/A output (12 channels)
-SPU Modified voltage range 30...1200 VRMS (max. input voltage 1000 VRMSf), frequency range DC...30 kHz. A calibration protocol has to be ordered separately instead of standard test certificate.
-SPI0,05 Modified current range 25 mARMS...1 ARMS. A calibration protocol has to be ordered separately instead of standard test certificate.
-SPI0,1 Modified current range 50 mARMS...2 ARMS. A calibration protocol has to be ordered separately instead of standard test certificate.
 

 

 

Our service:


One-stop service from manufacture to shipping.
1. Your inquiry related to our products or prices will be replied in 24hours.
2. Well-trained and experienced staffs to answer all your enquires influent English.
3. Distributor ship is offered for your unique desigh and some our current models.
4. Protection of your sales area, ideas of design and all your private information.

 

 

FAQ:


1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

 

Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions 0Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions 1Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions 2Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions 3

 

good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
RF Power Meter
Created with Pixso. Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions

Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions

Brand Name: Yokogawa
Model Number: WT332E
MOQ: 1 set
Price: Negotiation
Packaging Details: carton
Payment Terms: T/T
Detail Information
Place of Origin:
Japan
Brand Name:
Yokogawa
Certification:
ISO17025
Model Number:
WT332E
Product Name:
Power Meter
Current Measurement Range Direct Input:
6 Measuring Ranges/0.5...20 A
Frequency Bandwidth::
DC 0.1 Hz...100 KHz
Condition:
Pre-Owned
Functions:
Tested, In Full Working Conditions
Sampling Rate:
100 KS/s (16 Bit)
Minimum Order Quantity:
1 set
Price:
Negotiation
Packaging Details:
carton
Payment Terms:
T/T
Supply Ability:
in stock
Highlight:

Yokogawa WT332E power analyzer

,

2 phase digital watt meter

,

tested RF power analyzer

Product Description

Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions

 

Description of Yokogawa WT332E Power Meter

 

2-phase digital Watt meter.
Basic accuracy (50/60 Hz): ±(0.1% from measured power value + 0.05% from RMS measurement range), 6 voltage ranges 15...600 VRMS (Crest factor 3), 6 current ranges 0.5 ARMS...20 ARMS (Crest factor 3). Measurement of VRMS, Vmean, VDC, Vpeak, ARMS, ADC, Apeak, W, VA, var, cos phi, deg, ±Wh, ±Ah, CF, h, Hz and math. functions. Standard with integrator, measurement data memory, max. value memory, filter and frequency counter.
Standard with USB interface, GPIB/IEEE488.2, or RS232C interface (pease select), test certificate.

Features of Yokogawa WT333E Power Meter

 

Benefits of the Yokogawa WT332E 2-phase Digital Watt/Power Meter

  • 2-phase digital watt meter, high accuracy with fast display and data update.
  • Standby measurements according to IEC62301/EN50564, Energy Star and SPECpower.
  • Easy integration into PLC environments with Modbus/TCP (Ethernet).

 

The compact, 2-phase power meters of the WT332E series have a basic accuracy of ±(0.1% of reading + 0.05% of RMS range) and are ideal for precise measurement of power consumption of electrical devices, as well as for energy efficiency and energy saving studies. The lowest currents, for example, can be measured from 50 µA with specified accuracy.

  • Simultaneous harmonic analysis with high bandwidth.
  • Automatic adjustment of the data update rate.
  • Automatic range switching for integrating measurements.
  • Basic accuracy for power measurements (50/60 Hz): ±(0.1% of the measured value + 0.05% of the effective value measuring range).
  • Frequency bandwidth: DC, 0.1 Hz...100 kHz.
  • Current measurement range direct input:6 measuring ranges/0.5...20 A.
  • RMS voltage ranges: 6 measuring ranges/15...600 V.
  • External sensor input EX1: 2.5/5/10 V; EX2: 50/100/200/500 mV/1/2 V.
  • Signals with crest factors up to 300 measurable in all ranges.
  • Simultaneous measurement of RMS, MEAN, and DC voltage.
  • Frequency measurement: 2 channels (voltage and current).
  • 4x 7-segment LED displays
  • Sampling rate 100 kS/s (16 bit).
  • Data update rate 100/250/500 ms/1/2/5/10/20 s, Auto.
  • Harmonics analysis incl. THD calculation up to the 50th order available (option -G5).
  • Automatic range setting in integration mode.
  • Comparator function.
  • Interfaces: USB standard, GPIB/IEEE488 or RS232 (selectable), Ethernet (Modbus/TCP) available (option -C7).
  • Free PC application software WTViewerEfree for parameterization, control and data acquisition included in the scope of delivery.

Options

Option Description
Standard USB
-C1 GPIB/IEEE488 interface Please select one. Only one optionen (-C1 or -C2) can be selected for free.
-C2 RS232C interface
-C7 Ethernet interface incl. Modbus-TCP protocol
-EX1 External sensor input 2.5 V/5 V/10 V Only one can be selected at a time
-EX2 External sensor input 50 mV/100 mV/200 mV/500 mV/1 V/2 V
-G5 Harmonics measurement
-DA12 D/A output (12 channels)
-SPU Modified voltage range 30...1200 VRMS (max. input voltage 1000 VRMSf), frequency range DC...30 kHz. A calibration protocol has to be ordered separately instead of standard test certificate.
-SPI0,05 Modified current range 25 mARMS...1 ARMS. A calibration protocol has to be ordered separately instead of standard test certificate.
-SPI0,1 Modified current range 50 mARMS...2 ARMS. A calibration protocol has to be ordered separately instead of standard test certificate.
 

 

 

Our service:


One-stop service from manufacture to shipping.
1. Your inquiry related to our products or prices will be replied in 24hours.
2. Well-trained and experienced staffs to answer all your enquires influent English.
3. Distributor ship is offered for your unique desigh and some our current models.
4. Protection of your sales area, ideas of design and all your private information.

 

 

FAQ:


1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

 

Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions 0Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions 1Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions 2Reliable Yokogawa WT332E 2 phase Digital Power Analyzer Digital Watt Power Meter tested in good conditions 3