Send Message
good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
RF Power Meter
Created with Pixso. N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter

N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter

Brand Name: Agilent
Model Number: N1913A
MOQ: 1 set
Price: Negotiation
Payment Terms: T/T
Detail Information
Place of Origin:
Malaysia
Certification:
FCC
Product Name:
Power Meter
Form Factor:
Plug-In
Video Bandwidth:
400 MHz
Measurement Frequency Range:
200 (400)MHz To 4 GHz
Condition:
Pre-Owned
Functions:
Tested, In Full Working Conditions
Packaging Details:
carton
Supply Ability:
in stock
Highlight:

N1913A RF Power Meter

,

Microwave RF Power Meter

,

Rackmount Microwave Frequency Counter

Product Description

N1913A Agilent RF Power Meter

 

Description of N1913A RF Power Meter

 

Agilent N1913A and N1914A EPM Series power meters offer powerful new features, yet are code compatible with the popular E4418B and E4419B EPM power meters. With a reading rate at twice the speed (E-Series power sensors), flexibility of GPIB, LAN LXI-C or USB connectivity, making average power measurements has never been easier. You can connect two additional U2000 Series power sensors to the power meter via the optional USB hosts, transforming the N1913A and N1914A into 3-channel or 4-channel power meters. Plus, the new color display let you view and analyze test data more easily.

Features:

  • Frequency range of 9 kHz to 110 GHz (sensor dependent)
  • Wide dynamic range of -70 to +44 dBm (sensor dependent)
  • Speed improvement by 2X for E-Series sensors: up to 400 readings/sec
  • Go beyond GPIB with LAN LXI-C and USB connectivity
  • Enhanced user interface with high-resolution color display and numeric keypad
  • Code-compatible with 436A and 437B power meters
  • Increased measurement channels: up to three channels with two additional U2000 Series power sensors connected using the optional USB hosts
  • Automated frequency/power sweep measurements with the optional external trigger in/out feature

 

List of options
004 Delete Power Sensor Cable
005 Include Power Sensor Cable, 11730A Length 5-Ft (1.5m)
0L1 English language user guide, printed
101 Single Channel Average Power Meter
102 Single Channel Average Power Meter, Battery
103 Single Channel Average Power Meter, Battery, 2 Rears USB Ports
104 Single Channel Average Power Meter, VGA
105 Single Channel Average Power Meter, Battery, 1 Front 1 Rear USB Ports, VGA
106 Single Channel Average Power Meter, 1 Front 1 Rear USB Ports
107 Single Channel Average Power Meter, External Trigger In/Out
108 Parallel Rear Panel Sensor Input Connectors and Front Panel Reference Calibrator Connector, 2 Rear USB Ports
109 Parallel Rear Panel Sensor Input Connectors and Rear Panel Reference Calibrator Connector, 2 Rear USB Ports
11730A Sensor Cable 1.5m/5ft (11730A)
11730B Sensor Cable 3m/10ft (11730B)
11730C Sensor Cable 6.1m/20ft (11730C)
11730D Sensor Cable 15.2m/50ft (11730D
11730E Sensor Cable 30.5m/100ft (11730E)
167 Single Channel Average Power Meter; 1 Front 1 Rear USB Ports; External Trigger IN/OUT
1A7 ISO17025 Compliant Calibration Test Data
200 Code Compatibility for 436A and 437B
201 Single channel average power meter with VGA, trigger in/out, 1 front and 1 rear USB port
300 Battery pack - spare
34131A Transit case for half-rack 2U high instruments (e.g., 34401A)
34141A Yellow soft carry/operating case
34161A Accessory pouch for 34401A, 33120/250A, 34970A, 53131A, etc.
A6J ANSI/NCSL Z540 Compliance Calibration
C01 Front calibrator, front sensor
N1913A-004 Delete Power Sensor Cable
N1913A-005 Include Power Sensor Cable, 11730A Length 5-Ft (1.5m)
N1913A-0L1 English language user guide, printed
N1913A-101 Single Channel Average Power Meter
N1913A-102 Single Channel Average Power Meter, Battery
N1913A-103 Single Channel Average Power Meter, Battery, 2 Rears USB Ports
N1913A-104 Single Channel Average Power Meter, VGA
N1913A-105 Single Channel Average Power Meter, Battery, 1 Front 1 Rear USB Ports, VGA
N1913A-106 Single Channel Average Power Meter, 1 Front 1 Rear USB Ports
N1913A-107 Single Channel Average Power Meter, External Trigger In/Out
N1913A-108 Parallel Rear Panel Sensor Input Connectors and Front Panel Reference Calibrator Connector, 2 Rear USB Ports
N1913A-109 Parallel Rear Panel Sensor Input Connectors and Rear Panel Reference Calibrator Connector, 2 Rear USB Ports
N1913A-167 Single Channel Average Power Meter; 1 Front 1 Rear USB Ports; External Trigger IN/OUT
N1913A-1A7 ISO17025 Compliant Calibration Test Data
N1913A-200 Code Compatibility for 436A and 437B
N1913A-300 Battery pack - spare
N1913A-A6J ANSI/NCSL Z540 Compliance Calibration
N1918A Power Analysis Manager -N1918A
N1918A-100 N1918A Power Analyzer (with PC License)
N1918A-200 N1918A Power Analyzer (with USB License Key)
N6901A Standalone Upgrades for N1913A
N6901A-1FP Perpetual License - Code Compatibility for 436A and 437B
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
R-51B-001-3C Return to Agilent Warranty - 3 years
R-51B-001-5C Return to Agilent Warranty - 5 years
R-51B-001-C Return to Agilent Warranty - 1 year

N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter 0N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter 1N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter 2

 

 

 

FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

 

 

good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
RF Power Meter
Created with Pixso. N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter

N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter

Brand Name: Agilent
Model Number: N1913A
MOQ: 1 set
Price: Negotiation
Packaging Details: carton
Payment Terms: T/T
Detail Information
Place of Origin:
Malaysia
Brand Name:
Agilent
Certification:
FCC
Model Number:
N1913A
Product Name:
Power Meter
Form Factor:
Plug-In
Video Bandwidth:
400 MHz
Measurement Frequency Range:
200 (400)MHz To 4 GHz
Condition:
Pre-Owned
Functions:
Tested, In Full Working Conditions
Minimum Order Quantity:
1 set
Price:
Negotiation
Packaging Details:
carton
Payment Terms:
T/T
Supply Ability:
in stock
Highlight:

N1913A RF Power Meter

,

Microwave RF Power Meter

,

Rackmount Microwave Frequency Counter

Product Description

N1913A Agilent RF Power Meter

 

Description of N1913A RF Power Meter

 

Agilent N1913A and N1914A EPM Series power meters offer powerful new features, yet are code compatible with the popular E4418B and E4419B EPM power meters. With a reading rate at twice the speed (E-Series power sensors), flexibility of GPIB, LAN LXI-C or USB connectivity, making average power measurements has never been easier. You can connect two additional U2000 Series power sensors to the power meter via the optional USB hosts, transforming the N1913A and N1914A into 3-channel or 4-channel power meters. Plus, the new color display let you view and analyze test data more easily.

Features:

  • Frequency range of 9 kHz to 110 GHz (sensor dependent)
  • Wide dynamic range of -70 to +44 dBm (sensor dependent)
  • Speed improvement by 2X for E-Series sensors: up to 400 readings/sec
  • Go beyond GPIB with LAN LXI-C and USB connectivity
  • Enhanced user interface with high-resolution color display and numeric keypad
  • Code-compatible with 436A and 437B power meters
  • Increased measurement channels: up to three channels with two additional U2000 Series power sensors connected using the optional USB hosts
  • Automated frequency/power sweep measurements with the optional external trigger in/out feature

 

List of options
004 Delete Power Sensor Cable
005 Include Power Sensor Cable, 11730A Length 5-Ft (1.5m)
0L1 English language user guide, printed
101 Single Channel Average Power Meter
102 Single Channel Average Power Meter, Battery
103 Single Channel Average Power Meter, Battery, 2 Rears USB Ports
104 Single Channel Average Power Meter, VGA
105 Single Channel Average Power Meter, Battery, 1 Front 1 Rear USB Ports, VGA
106 Single Channel Average Power Meter, 1 Front 1 Rear USB Ports
107 Single Channel Average Power Meter, External Trigger In/Out
108 Parallel Rear Panel Sensor Input Connectors and Front Panel Reference Calibrator Connector, 2 Rear USB Ports
109 Parallel Rear Panel Sensor Input Connectors and Rear Panel Reference Calibrator Connector, 2 Rear USB Ports
11730A Sensor Cable 1.5m/5ft (11730A)
11730B Sensor Cable 3m/10ft (11730B)
11730C Sensor Cable 6.1m/20ft (11730C)
11730D Sensor Cable 15.2m/50ft (11730D
11730E Sensor Cable 30.5m/100ft (11730E)
167 Single Channel Average Power Meter; 1 Front 1 Rear USB Ports; External Trigger IN/OUT
1A7 ISO17025 Compliant Calibration Test Data
200 Code Compatibility for 436A and 437B
201 Single channel average power meter with VGA, trigger in/out, 1 front and 1 rear USB port
300 Battery pack - spare
34131A Transit case for half-rack 2U high instruments (e.g., 34401A)
34141A Yellow soft carry/operating case
34161A Accessory pouch for 34401A, 33120/250A, 34970A, 53131A, etc.
A6J ANSI/NCSL Z540 Compliance Calibration
C01 Front calibrator, front sensor
N1913A-004 Delete Power Sensor Cable
N1913A-005 Include Power Sensor Cable, 11730A Length 5-Ft (1.5m)
N1913A-0L1 English language user guide, printed
N1913A-101 Single Channel Average Power Meter
N1913A-102 Single Channel Average Power Meter, Battery
N1913A-103 Single Channel Average Power Meter, Battery, 2 Rears USB Ports
N1913A-104 Single Channel Average Power Meter, VGA
N1913A-105 Single Channel Average Power Meter, Battery, 1 Front 1 Rear USB Ports, VGA
N1913A-106 Single Channel Average Power Meter, 1 Front 1 Rear USB Ports
N1913A-107 Single Channel Average Power Meter, External Trigger In/Out
N1913A-108 Parallel Rear Panel Sensor Input Connectors and Front Panel Reference Calibrator Connector, 2 Rear USB Ports
N1913A-109 Parallel Rear Panel Sensor Input Connectors and Rear Panel Reference Calibrator Connector, 2 Rear USB Ports
N1913A-167 Single Channel Average Power Meter; 1 Front 1 Rear USB Ports; External Trigger IN/OUT
N1913A-1A7 ISO17025 Compliant Calibration Test Data
N1913A-200 Code Compatibility for 436A and 437B
N1913A-300 Battery pack - spare
N1913A-A6J ANSI/NCSL Z540 Compliance Calibration
N1918A Power Analysis Manager -N1918A
N1918A-100 N1918A Power Analyzer (with PC License)
N1918A-200 N1918A Power Analyzer (with USB License Key)
N6901A Standalone Upgrades for N1913A
N6901A-1FP Perpetual License - Code Compatibility for 436A and 437B
R-50C-011-3 Agilent Calibration - 3 years
R-50C-011-5 Agilent Calibration - 5 years
R-50C-021-3 ANSI Z540-1-1994 Calibration - 3 years
R-50C-021-5 ANSI Z540-1-1994 Calibration - 5 years
R-51B-001-3C Return to Agilent Warranty - 3 years
R-51B-001-5C Return to Agilent Warranty - 5 years
R-51B-001-C Return to Agilent Warranty - 1 year

N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter 0N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter 1N1913A Agilent RF Power Meter Rackmount Kit Microwave Frequency Counter 2

 

 

 

FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .