Brand Name: | Fluke |
Model Number: | 376FC |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | T/T |
Fluke New Fluke 376 FC True-RMS Clamp Meter with iFlex 1000 V AC or DC
Product overview of Fluke 376 FC True-RMS Clamp Meter with iFlex
The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.
The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.
Features of New Fluke 376 FC True-RMS Clamp Meter
Specification of New Fluke 376 FC True-RMS Clamp Meter
General Specifications | |||||
AC Current via Jaw | |||||
Range | 999.9 A | ||||
Resolution | 0.1 A | ||||
Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | ||||
2.5% ±5 digits (100-500 Hz) | |||||
Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | ||||
2.5 @ 600 A | |||||
Add 2% for C.F. >2 | |||||
AC Current via Flexible Current Probe | |||||
Range | 2500 A | ||||
Resolution | 0.1 A (≤ 600 A) | ||||
1 A (≤ 2500 A) | |||||
Accuracy | 3% ±5 digits (5 – 500 Hz) | ||||
Crest Factor (50/60Hz) | 3.0 at 1100 A | ||||
2.5 at 1400 A | |||||
1.42 at 2500 A | |||||
Add 2% for C.F. > 2 | |||||
i2500-10 Flex | i2500-18 Flex | i2500-36 Flex | |||
A | |||||
Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | 4.8 in (122.2 mm) | ||
Error | ±0.5 % | ±0.5 % | ±0.5 % | ||
B | |||||
Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | 5.3 in (133.6 mm) | ||
Error | ±1.0 % | ±1.0 % | ±1.0 % | ||
C | |||||
Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | 5.8 in (147.6 mm) | ||
Error | ±2.0 % | ±2.0 % | ±2.0 % | ||
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | |||||
DC Current | |||||
Range | 999.9 A | ||||
Resolution | 0.1 A | ||||
Accuracy | 2% ±5 digits | ||||
AC Voltage | |||||
Range | 1000 V | ||||
Resolution | 0.1 V (≤600.0 V) | ||||
1 V (≤1000 V) | |||||
Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | ||||
DC Voltage | |||||
Range | 1000 V | ||||
Resolution | 0.1 V (≤600.0 V) | ||||
1 V (≤1000 V) | |||||
Accuracy | 1% ±5 digits | ||||
mV dc | |||||
Range | 500.0 mV | ||||
Resolution | 0.1 mV | ||||
Accuracy | 1% ±5 digits | ||||
Frequency via Jaw | |||||
Range | 5.0 Hz to 500.0 Hz | ||||
Resolution | 0.1 Hz | ||||
Accuracy | 0.5% ±5 digits | ||||
Trigger level | 5 Hz to 10 Hz, ≥10 A | ||||
10 Hz to 100 Hz, ≥5 A | |||||
100 Hz to 500 Hz, ≥10 A | |||||
Frequency via Flexible Current Probe | |||||
Range | 5.0 Hz to 500.0 Hz | ||||
Resolution | 0.1 Hz | ||||
Accuracy | 0.5% ±5 digits | ||||
Trigger level | 5 Hz to 20 Hz, ≥25 A | ||||
20 Hz to 100 Hz, ≥20 A | |||||
100 Hz to 500 Hz, ≥25 A | |||||
Resistance | |||||
Range | 60 kΩ | ||||
Resolution | 0.1 Ω (≤600 Ω) | ||||
1 Ω (≤6000 Ω) | |||||
10 Ω (≤60 kΩ) | |||||
Accuracy | 1% ±5 digits | ||||
Capacitance | |||||
Range | 1000 μF | ||||
Resolution | 0.1 μF (≤ 100 μF) | ||||
1 μ F (≤ 1000 μF) | |||||
Accuracy | 1% ±4 digits |
Models of Fluke 376 FC True-RMS Clamp Meter with iFlex
Fluke 376 FC with 18-inch iFlex
Includes:
Fluke 376 FC with 36-inch iFlex
Includes:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .
Brand Name: | Fluke |
Model Number: | 376FC |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | T/T |
Fluke New Fluke 376 FC True-RMS Clamp Meter with iFlex 1000 V AC or DC
Product overview of Fluke 376 FC True-RMS Clamp Meter with iFlex
The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.
The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.
Features of New Fluke 376 FC True-RMS Clamp Meter
Specification of New Fluke 376 FC True-RMS Clamp Meter
General Specifications | |||||
AC Current via Jaw | |||||
Range | 999.9 A | ||||
Resolution | 0.1 A | ||||
Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | ||||
2.5% ±5 digits (100-500 Hz) | |||||
Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | ||||
2.5 @ 600 A | |||||
Add 2% for C.F. >2 | |||||
AC Current via Flexible Current Probe | |||||
Range | 2500 A | ||||
Resolution | 0.1 A (≤ 600 A) | ||||
1 A (≤ 2500 A) | |||||
Accuracy | 3% ±5 digits (5 – 500 Hz) | ||||
Crest Factor (50/60Hz) | 3.0 at 1100 A | ||||
2.5 at 1400 A | |||||
1.42 at 2500 A | |||||
Add 2% for C.F. > 2 | |||||
i2500-10 Flex | i2500-18 Flex | i2500-36 Flex | |||
A | |||||
Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | 4.8 in (122.2 mm) | ||
Error | ±0.5 % | ±0.5 % | ±0.5 % | ||
B | |||||
Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | 5.3 in (133.6 mm) | ||
Error | ±1.0 % | ±1.0 % | ±1.0 % | ||
C | |||||
Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | 5.8 in (147.6 mm) | ||
Error | ±2.0 % | ±2.0 % | ±2.0 % | ||
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | |||||
DC Current | |||||
Range | 999.9 A | ||||
Resolution | 0.1 A | ||||
Accuracy | 2% ±5 digits | ||||
AC Voltage | |||||
Range | 1000 V | ||||
Resolution | 0.1 V (≤600.0 V) | ||||
1 V (≤1000 V) | |||||
Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | ||||
DC Voltage | |||||
Range | 1000 V | ||||
Resolution | 0.1 V (≤600.0 V) | ||||
1 V (≤1000 V) | |||||
Accuracy | 1% ±5 digits | ||||
mV dc | |||||
Range | 500.0 mV | ||||
Resolution | 0.1 mV | ||||
Accuracy | 1% ±5 digits | ||||
Frequency via Jaw | |||||
Range | 5.0 Hz to 500.0 Hz | ||||
Resolution | 0.1 Hz | ||||
Accuracy | 0.5% ±5 digits | ||||
Trigger level | 5 Hz to 10 Hz, ≥10 A | ||||
10 Hz to 100 Hz, ≥5 A | |||||
100 Hz to 500 Hz, ≥10 A | |||||
Frequency via Flexible Current Probe | |||||
Range | 5.0 Hz to 500.0 Hz | ||||
Resolution | 0.1 Hz | ||||
Accuracy | 0.5% ±5 digits | ||||
Trigger level | 5 Hz to 20 Hz, ≥25 A | ||||
20 Hz to 100 Hz, ≥20 A | |||||
100 Hz to 500 Hz, ≥25 A | |||||
Resistance | |||||
Range | 60 kΩ | ||||
Resolution | 0.1 Ω (≤600 Ω) | ||||
1 Ω (≤6000 Ω) | |||||
10 Ω (≤60 kΩ) | |||||
Accuracy | 1% ±5 digits | ||||
Capacitance | |||||
Range | 1000 μF | ||||
Resolution | 0.1 μF (≤ 100 μF) | ||||
1 μ F (≤ 1000 μF) | |||||
Accuracy | 1% ±4 digits |
Models of Fluke 376 FC True-RMS Clamp Meter with iFlex
Fluke 376 FC with 18-inch iFlex
Includes:
Fluke 376 FC with 36-inch iFlex
Includes:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .