logo
good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Electronic Test And Measurement Equipment
Created with Pixso. Fluke 52120A Transconductance Amplifier with 10 kHz Frequency 120 A AC Current and 140 ppm Accuracy

Fluke 52120A Transconductance Amplifier with 10 kHz Frequency 120 A AC Current and 140 ppm Accuracy

Brand Name: Fluke
Model Number: 52120A
MOQ: 1 set
Price: Negotiation
Payment Terms: T/T
Detail Information
Place of Origin:
USA
Certification:
ISO:17025 Accredited Calibration
Product Name:
Transconductance Amplifier
Brand:
FLUKE
Condition:
Pre-Owned
Functions:
Tested, In Full Working Conditions
Frequency:
To 10 KHz
Supply Ability:
in stock
Highlight:

Fluke 52120A Transconductance Amplifier

,

52120A Transconductance Amplifier

,

10 kHz Frequency Transconductance Amplifier

Product Description
Fluke 52120A Transconductance Amplifier Pre-Owned Up To 10 kHz Frequency
Product Overview

The Fluke 52120A is a transconductance amplifier designed to enhance calibration capabilities in laboratory environments. It addresses limitations in output current, accuracy, and drive capability of existing test equipment, making it ideal for calibration laboratories, electrical utilities, and manufacturers of power/energy instrumentation, meters, power quality analyzers, and power converters.

The Fluke Calibration 52120A Transconductance Amplifier supplies DC current up to 100 amps and AC current up to 120 amps with accuracies to 140 ppm. Using accessory coils, it can generate 3,000 or 6,000 amps. Three units connected in parallel can output up to 360 amps, with inductive drive capability of 1 mH and compliance voltage of 4.5 volts supporting a wide range of applications.

Key Features
  • High-Current Output: Supplies up to 100 A DC and 120 A AC current. With accessory coils, generates 3000 A or 6000 A. Three units in parallel output up to 360 A.
  • High-Accuracy Calibration: Accuracy up to 140 ppm for precise calibration of high-current working load devices including power/energy meters, clamp meters, and current transformers.
  • Wide Frequency Range: DC to 10 kHz frequency range meets diverse calibration requirements.
  • Multiple Operating Modes: Supports parallel operation of 2-3 amplifiers up to 360 A single-phase, or up to 10 amplifiers and 1200 A in standalone mode. Closed-loop mode communicates seamlessly with Fluke Calibration 6105A or 6100B electrical power standards.
Performance Specifications
Industry-leading amplifier accuracy 140 ppm AC (with 61XXA Electrical Power Standard)
350 ppm AC (with DC/LF calibrator)
160 ppm DC (with DC/LF calibrator)
Frequency DC to 10 kHz
Burden voltage (compliance) 4.5 V @ 120 A
Inductive drive capability 1 mH load
Output ranges 2 A, 20 A, 120 A
Input ranges 2 V or 200 mA F.S. for 2 A and 20 A ranges
1.2 V or 120 mA F.S. for 120 A range
Parallel operation Closed loop with 61XXX: 2-3 amplifiers, up to 360 A single-phase
Standalone: up to 10 amplifiers, up to 1200 A single-phase
Accessory coils 25-turn coil supports 3000 A
50-turn coil supports 6000 A
Control communication With 6105A/6100B Electrical Power Standards
Remote operation GPIB
Technical Specifications
Parameter Specifications
Input current ranges 200 mA, 200 mA, 120 mA (100 mA DC)
Input voltage ranges 2 V, 2 V, 1.2 V (1.0 V DC)
Output ranges 2 A, 20 A, 120 A (100 A DC)
Current gains 10, 100, 1000
Transconductances 1, 10, 100 siemens
Output compliance voltage 4.5 Vrms (6.4 Vp)
Output isolation 600 Vrms, 850 Vp, DC up to 850 Hz
Operating temperature 5 °C to 35 °C
Calibration temperature range 16 °C to 30 °C
Warm-up time 1 hour
Power consumption < 1500 VA
Weight 25 kg
Design Standards and Compliance

Designed in accordance with EN 61010-1:2010, CAN/CSA 22.2 No 61010.1-04, ANSI/UL 61010-1:2004, and EN 61326-1:2006, with CE marking and CSA certification.

Available Options
Option Code Description
COIL12V Coil 12 V DC Supply
COIL3KA Coil, 25 Turn, 3000 Amp
COIL6KA Coil, 50 Turn, 6000 Amp
Our Service
  • One-stop service from manufacture to shipping
  • Inquiries replied within 24 hours
  • Well-trained English-speaking staff
  • Distributor support for unique designs and current models
  • Protection of sales areas, design ideas, and private information
Frequently Asked Questions
Can you ship orders to Canada or Australia?

Yes, we ship worldwide.

What delivery methods do you use and what is the delivery time?

We ship via EMS, DHL, FedEx, UPS, TNT with tracking numbers. Delivery time is typically 4-7 business days.

What is your payment term?

100% T/T payment before shipment.

How can I ask any other questions?

You can contact us online or leave messages below.

Product Images
Fluke 52120A Transconductance Amplifier with 10 kHz Frequency 120 A AC Current and 140 ppm Accuracy 0 Fluke 52120A Transconductance Amplifier with 10 kHz Frequency 120 A AC Current and 140 ppm Accuracy 1 Fluke 52120A Transconductance Amplifier with 10 kHz Frequency 120 A AC Current and 140 ppm Accuracy 2
Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

M
M*n
United States Dec 12.2024
good supplier
L
L*y
France Oct 17.2024
good working condition
F
f*x
Nigeria Oct 12.2024
great product,works flawlessly