logo
good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Mixed Signal Oscilloscope
Created with Pixso. RTM3000 Digital Oscilloscope with 1GHz Bandwidth 80 Msample Memory and 10-bit ADC Resolution

RTM3000 Digital Oscilloscope with 1GHz Bandwidth 80 Msample Memory and 10-bit ADC Resolution

Brand Name: Rohde & Schwarz
Model Number: RTM3000
MOQ: 1 set
Price: Negotiable
Delivery Time: 1~3 Working Days
Payment Terms: T/T,Western Union
Detail Information
Place of Origin:
Germany
Certification:
ISO17025
Resolution:
1280 × 800 Pixel (WXGA)
Channels:
2/4
Bandwidth In MHz:
100, 200, 350, 500, 1000
Maximum Memory:
40/channel, 80 Interleaved; 400 Msample (optional) ­segmented Memory
Temperature Loading:
0 °C To +50 °C (operating), –40 °C To +70 °C (storage)
Dimensions In Mm (W × H × D):
390 × 220 × 152
Weight (kg):
3.3
AC Supply:
100 V To 240 V At 50 Hz To 60 Hz 1.6 A To 0.7 A
Packaging Details:
Carton
Supply Ability:
In Stock
Highlight:

1GHz RTM3000 Oscilloscope

,

80 Interleaved Maximum Memory Oscilloscope

,

2/4 Channels RTM3000 Oscilloscope

Product Description
100 MHz to 1GHz RTM3000 Oscilloscope with 80 Interleaved Maximum Memory and 2/4 Channels
Key Features
  • Bandwidth: 100 MHz to 1GHz
  • Sample rate: up to 5 Gsample/s
  • Memory depth: up to 80 Msample
  • ADC resolution: 10-bit
  • Display: 10.1'' capacitive touchscreen
Oscilloscope Comparison
Specification R&S®RTC1000 R&S®RTB2000 R&S®RTM3000 R&S®RTA4000
Number of oscilloscope channels 2 2/4 2/4 4
Bandwidth in MHz 50, 70, 100, 200, 300 70, 100, 200, 300 100, 200, 350, 500, 1000 200, 350, 500, 1000
Maximum sampling rate in Gsample/s 1/channel, 2 interleaved 1.25/channel, 2.5 interleaved 2.5/channel, 5 interleaved 2.5/channel, 5 interleaved
Maximum memory depth in Msample 1/channel, 2 interleaved 10/channel, 20 interleaved; 160 Msample (optional) segmented memory 40/channel, 80 interleaved; 400 Msample (optional) segmented memory 100/channel, 200 interleaved; 1 Gsample (standard) segmented memory
Timebase accuracy in ppm 50 2.5 2.5 0.5
Vertical bits (ADC) 8 10 10 10
Minimum input sensitivity 1 mV/div 1 mV/div 500 µV/div 500 µV/div
Display 6.5", 640 × 480 pixel 10" capacitive touch, 1280 × 800 pixel 10" capacitive touch, 1280 × 800 pixel 10" capacitive touch, 1280 × 800 pixel
Update rate 10000 waveforms/s 300000 waveforms/s in fast segmented memory mode 2000000 waveforms/s in fast segmented memory mode 2000000 waveforms/s in fast segmented memory mode
MSO 8 channels, 1 Gsample/s 16 channels, 2.5 Gsample/s 16 channels, 5 Gsample/s 16 channels, 5 Gsample/s
Protocol (optional) I2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN I2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN I2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN, audio (I²S/LJ/RJ/TDM), ARINC, MIL I2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN, audio (I²S), ARINC, MIL
Generator(s) 1 generator, 4-bit pattern generator 1 ARB, 4-bit pattern generator 1 ARB, 4-bit pattern generator 1 ARB, 4-bit pattern generator
Math +,-, *,/,FFT(128k points) +,-, *,/,FFT(128k points) +,-, *,/,FFT(128k points), 21 advanced functions +,-, *,/,FFT(128k points), 21 advanced functions
Rohde&Schwarz probe interface - - standard standard
RF capability FFT FFT spectrum analysis spectrum analysis
Key Benefits
SEE SMALL SIGNAL DETAILS IN THE PRESENCE OF LARGE SIGNALS
  • 10-bit ADC: 1024 levels, 4 times more than 8-bit ADC
  • 500 µV/div: full bandwidth, no software magnification
CAPTURE MORE TIME AT FULL BANDWIDTH
  • 80 Msample: standard acquisition memory 8 to 40 times better
  • 5 Gsample: fast sampling rate
  • 400 Msample: segmented memory
10.1" HIGH-RESOLUTION CAPACITIVE TOUCHSCREEN WITH GESTURE SUPPORT
X-IN-1 OSCILLOSCOPE
  • Oscilloscope
  • Logic analyzer
  • Protocol analyzer
  • Waveform and pattern generator
  • Digital voltmeter
  • Frequency analysis mode
  • Mask test mode
  • History and segmented memory mode
FREQUENCY RESPONSE ANALYSIS (BODE PLOT)
  • Analyze the frequency response of passive filters and amplifier circuits
  • Perform control loop response measurements
  • Perform power supply rejection ratio measurements
  • Simple and fast documentation
THE BEST CHOICE FOR POWER
  • Analyze the input, output and transfer function of switched-mode power supplies
  • Measurement wizard for fast results
  • Simple and fast documentation
  • Analyze harmonic current in line with conventional EN, MIL and RTCA standards
SPECTRUM ANALYSIS: IDENTIFY INTERACTIONS BETWEEN TIME AND FREQUENCY
  • Spectrogram: evolution over time
  • Peak markers: automatic positioning
PROTOCOL ANALYSIS: EFFICIENTLY DEBUG SERIAL BUSES
THE RIGHT PROBE FOR THE BEST MEASUREMENT
  • More than 30 dedicated probes
  • Micro button for convenient instrument control
  • 0.01% accuracy with R&S®ProbeMeter
Specifications in Brief
Category Model/Configuration Specification
Vertical system Number of channels R&S®RTM3002; R&S®RTM3004 | 2; 4
Bandwidth (-3 dB) at 50 Ω R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) | 100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz
Rise time (calculated) R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) | 3.5 ns, 1.75 ns, 1 ns, 700 ps, 350 ps
Input impedance 50 Ω ± 1.5% (meas.), 1 MΩ ± 1% (meas.) || 14 pF ± 1 pF (meas.)
Input sensitivity max. bandwidth in all ranges
at 1 MΩ 500 µV/div to 10 V/div
at 50 Ω 500 µV/div to 1 V/div
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5°C after self-alignment
input sensitivity > 5 mV/div ±1.5% of full scale
input sensitivity ≤ 5 mV/div ±2% of full scale
ADC resolution 10 bit, up to 16 bit with high resolution decimation
Acquisition system Maximum realtime sampling rate 2.5 Gsample/s; 5 Gsample/s, interleaved
Acquisition memory standard; with R&S®RTM-K15 option 40 Msample (80 Msample interleaved); 400 Msample segmented memory
Horizontal system Timebase range selectable between 0.5 ns/div and 500 s/div
Trigger system Trigger types standard edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus, timeout
Trigger types option I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN, ARINC429, MIL-STD-1553
MSO option Digital channels 16 (2 logic probes)
Sampling rate 1.25 Gsample/s
Acquisition memory standard; with R&S®RTM-K15 option | 40 Msample (80 Msample interleaved); 400 Msample segmented memory
Waveform generator Resolution, sample rate 14 bit, 250 Msample/s
Amplitude high Z; 50 Ω 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp)
DC offset high Z; 50 Ω ±5 V; ±2.5 V
Signal forms frequency ranges sine 0.1 Hz to 25 MHz
Signal forms frequency ranges pulse/rectangle 0.1 Hz to 10 MHz
Signal forms frequency ranges ramp/triangle 0.1 Hz to 1 MHz
Signal forms frequency ranges noise max. 25 MHz
Arbitrary sampling rate; memory depth max. 10 Msample/s; 32k points
General data Screen 10.1" WXGA TFT color display (1280 × 800 pixel)
Interfaces USB host with MTP, USB device, LAN, powerful web server for remote display and operation
Audible noise 28.3 dB(A)
Dimensions 390 mm × 220 mm × 152 mm (15.4 in × 8.66 in × 5.98 in)
Weight 3.3 kg (7.27 lb)
Frequently Asked Questions
Q: What delivery methods do you use, and what is the delivery time?
A: We ship via EMS, DHL, FedEx, UPS, and TNT with tracking numbers. Delivery typically takes 4-7 business days.
Q: How are duties and taxes handled?
A: Duties and taxes vary by country and are usually the buyer's responsibility. Please check local import regulations for details.
Q: What are your payment terms?
A: We require 100% T/T payment before shipment.
Q: How can I ensure the quality of products purchased internationally?
A: We work with reputable suppliers and conduct thorough inspections before shipping. Warranties are available for most products--please check for specific terms.
Q: What should I do if my shipment is delayed?
A: Check the tracking information provided. If there are delays, contact us or the carrier directly for updates.
Q: Do you offer discounts for bulk orders?
A: Yes, discounts may be available for bulk purchases. Please contact us to discuss your specific requirements.
RTM3000 Digital Oscilloscope with 1GHz Bandwidth 80 Msample Memory and 10-bit ADC Resolution 0 RTM3000 Digital Oscilloscope with 1GHz Bandwidth 80 Msample Memory and 10-bit ADC Resolution 1 RTM3000 Digital Oscilloscope with 1GHz Bandwidth 80 Msample Memory and 10-bit ADC Resolution 2
Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

S
S*l
France Jan 29.2026
Transaction facile.
M
M*
United States Oct 16.2025
Nice seller, Good device.
M
M*l
Singapore Apr 8.2025
Seller shipped with a lot of packaging protection and the intrument in excellent condition inside the case.