| Brand Name: | Tektronix |
| Model Number: | TDS7000B |
| MOQ: | 1 set |
| Price: | Negotiable |
| Delivery Time: | 1~3 Working Days |
| Payment Terms: | T/T,Western Union |
The TDS7000B Series' unique combination of superior measurement fidelity, unrivaled analysis, and uncompromised usability makes it the ultimate test machine to simplify and speed the design of high-speed, complex systems. This family offers the industry's best solution to the challenging signal integrity issues faced by designers verifying, characterizing, and debugging sophisticated electronic designs.
They deliver up to 7.25 GHz (typical) true analog bandwidth, down to 43 ps rise time (20% - 80%), and 20 GS/s maximum real-time sample rate to capture critical events with fine detail. Exclusive DPX® acquisition technology enables waveform capture rates up to 400,000 wfms/s to quickly find rare glitches in seconds or minutes, instead of hours or days. Innovative software solutions deliver domain expertise for advanced analysis and compliance testing, while the OpenChoice® architecture enables users to integrate their expertise through the ability to easily write custom programs or utilize popular commercial software. The intuitive graphical user interface delivers sophisticated capability to advanced users without intimidating occasional users.
MyScope control win allow you to build your own control win with only the controls, features, and capabilities that you care about and are important in your job. For the first time you can create your own personalized "toolbox" of oscilloscope features. No longer do you need to search through menus for features or re-learn how to drive the oscilloscope after a break from the lab. MyScope control win are easily created in a matter of minutes using a simple, visual, drag and drop process. Once created, these customized win are easily accessed through a dedicated MyScope button and menu selection on the oscilloscope button/menu bar, just like any other control window. You can make an unlimited number of custom control win, enabling each person who uses the oscilloscope, in a shared environment, to have their own unique control window. Since the control win are stored as files on the hard drive, they can easily be transferred to other CSA7000B, TDS5000B, or TDS6000B/C Series oscilloscopes, or they can even be e-mailed to a co-worker around the world when the need arises. MyScope control win will benefit all oscilloscope users, from eliminating the ramp-up time that many face when returning to the lab after not using an oscilloscope for a while, to the power user who can now operate far more efficiently. Everything you need is found in one control window rather than having to constantly navigate through menu after menu to repeat similar tasks.
Right mouse click menus make simple things as they should be - simple. Right click menus are context sensitive, meaning the choices presented in the menu depend on where you right clicked the mouse. This makes right click menus extremely intuitive. Want to change the cursor type? Right click on a cursor or the cursor readouts. Want to change the reference levels of an automatic measurement? Right click on the measurement. Want to change trigger parameters? Right click on the trigger readouts. Want to change a waveform's color? Right click on the waveform handle. Virtually all objects on the oscilloscope display have right click menus associated with them that include all the appropriate actions or features relative to those objects. There are also right click menus for regions of the display in addition to just objects. For example, right clicking in the main graticule brings up a menu with choices such as Clear Data, Default Setup, Autoset, Screen Captures, Save All Waveforms, and Add Screen Text, providing single click access to many of your most commonly performed tasks.
| TDS7054 | TDS7104 | TDS7154B | TDS7254B | TDS7404B | TDS7704B | |
|---|---|---|---|---|---|---|
| Input Channels | 4 | 4 | 4 | 4 | 4 | 4 |
| Hardware Analog Bandwidth (-3 dB) | 500 MHz | 1 GHz | 1.5 GHz*1 | 2.5 GHz*1 | 4 GHz*1 | 7.25 GHz*1 (typical), 7GHz*1 guaranteed |
| Rise Time 10% to 90% (Typical) | 800 ps | 400 ps | 200 ps | 130 ps | 100 ps | 62 ps |
| Rise Time 20% to 80% (Typical) | 135 ps | 83 ps | 72 ps | 43 ps | ||
| DC Gain Accuracy | 1% | ±(2% + (2% × offset)) | ±2.5% + (2% × offset) | |||
| TDS7054/TDS7104 | TDS7154B/TDS7254B/TDS7404B/TDS7704B | |
|---|---|---|
| Hardware Bandwidth Limits | 250 MHz or 20 MHz | Requires TCA-1 MEG |
| Input Coupling | AC, DC, GND | DC, GND |
| Input Impedance | 1 MΩ ±0.5% or 50 Ω ±1% | 50 Ω ±2.5% |
| Input Sensitivity, 1 MΩ | 1 mV/div to 10 V/div | -- |
| Input Sensitivity, 50 Ω | 1 mV/div to 1 V/div | 2 mV/div to 1 V/div |
| Vertical Resolution | 8-Bit (>11-Bit with averaging) | 8-Bit (>11-Bit with averaging) |
| Max Input Voltage, 1 MΩ | ±150 V CAT I Derate at 20 dB/decade to 9 VRMS above 200 kHz | -- |
| Max Input Voltage, 50 Ω | 5 VRMS, with peaks less than ±30 Volts | <1 VRMS for <100 mV/div, <5 VRMS for ≥100 mV/div settings. Also determined by TekConnect® accessory |
| Offset Range | 1 mV/div to 100 mV/div: ±1 V 101 mV/div to 1 V/div: ±10 V 1.01 V/div to 10 V/div: ±100 V |
2 mV to 50 mV/div: ±0.5 V 50.5 mV to 99.5 mV: ±0.25 V 100 mV to 500 mV: ±5 V 505 mV to 1 V/div: ±2.5 V |
| Channel-to-channel Isolation Any Two Channels at Equal Vertical Scale Settings | ≥100:1 at 100 MHz and ≥30:1 at the rated bandwidth | ≥80:1 at 1.5 GHz and ≥15:1 at the rated bandwidth |
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews