| Brand Name: | Fluke |
| Model Number: | 5520A |
| MOQ: | 1 set |
| Price: | Negotiation |
| Payment Terms: | T/T |
The Fluke 5520A builds on the 5500A's capabilities, extending its workload coverage even further. Its improved accuracy, expanded ranges, and capability to calibrate 5½ and 6½ digit multimeters can cover virtually all your high-performance workload, including handheld and bench meters (analog and digital) up to 6½ digits.
| DC voltage range | 0 - 1100V |
| DC current range | 0 - 11A |
| Resistance range | 0 - 330 MOhm |
| AC voltage range | 1.0mV - 1000V |
| AC current range | 0.033mA - 11A |
| Capacitance range | 0.33nf - 1.1mf |
| Voltage DC Range | 0 to ±1020V |
| Current DC Range | 0 to ±20.5A |
| Resistance Range | 0 to 1100 MΩ |
| Voltage AC Range | 1 mV to 1020V; 10 Hz to 500 kHz, Sine |
| Current AC Range | 29 mA to 20.5A; 10 Hz to 30 kHz, Sine |
| Capacitance Range | 0.19 nF to 110 mF |
| Thermocouple Source and Measure Range | -250°C to +2316°C (11 types) |
| RTD Source Range | -200°C to +630°C (8 types) |
| DC Power Range | 10.9 mW to 20.5 kW |
| AC Power Range | 10.9 mW to 20.5 kW; 45-65 Hz, PF=1 |
| Phase Range | 0 to ± 179.99°; 10 Hz to 30 kHz |
| Frequency Range | 0.01 Hz to 2.0 MHz |
| Power Consumption | 600 VA |
| Warm up Time | Twice the time since last warmed up, to a maximum of 30 minutes |
| Settling Time | Less than 5 seconds for all functions and ranges except as noted |
| Standard Interfaces | IEEE-488 (GPIB), RS-232 |
| Safety | 12,200m (40,000 ft) maximum |
| Analog Low Isolation | 20V |
| EMC | Designed to comply with IEC 61326-1/1997 |
| Operating Temperature | 0°C to 50°C |
| Calibration Temperature | 15°C to 35°C |
| Storage Temperature | -20°C to 70°C |
| Temperature Coefficient | 10% of the 90-day specification per °C outside tcal ± 5°C |
| Operating Relative Humidity | <80% to 30°C, <70% to 40°C, <40% to 50°C |
| Storage Relative Humidity | <95%, non-condensing |
| Operating Altitude | 3,050m (10,000 ft) maximum |
| Non-operating Altitude | 12,200m (40,000 ft) maximum |
| Line Voltage (selectable) | 100V, 120V, 220V, 240V |
| Line Frequency | 47 to 63 Hz |
| Line Voltage Variation | + 10% about line voltage setting |
| Height | 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet |
| Width | 43.2 cm (17 in), standard rack width |
| Depth | 47.3 cm (18.6 in) overall |
| Option Code | Description |
|---|---|
| 06 | Bit serial asynchronous interface (RS-232-C) |
| 1613006 | 3YR CAL & REPAIR |
| 525A/LEADS | THERMOCOUPLE AND TEST LEADS |
| 5500/CAL-L | LICENSE FOR MET/BASE SOFTWARE |
| CASE | 5500A/CASE - TRANSIT CASE |
| Coil | 50 Turn Coil |
| MET/BASE-6 | METROLOGY SOFTWARE, REQUIRES MET/CAL-L |
| MET/BASE-7 | MET BASE 7 SOFTWARE |
| MET/CAL-L | CAL SOFTWARE USER LICENSE |
| PQ | Power Quality Option |
| PQ/6 | POWER QUALITY AND 600MHZ SCOPE CAL OPTS |
| RAC3YR | REPAIR & ACCR CAL 3YRS |
| SC1100 | 1100 MHz Oscilloscope Calibrator |
| SC2 | CALIBRATION SERVICE FOR 2 YEARS |
| SC300 | 300 MHz Oscilloscope Calibrator |
| SC600 | 600 MHz Oscilloscope Calibrator |
| Z540X2 | 2 YRS CALIBRATION |
Yes, we can. We send orders worldwide.
We can ship by EMS, DHL, FedEx, UPS, TNT with tracking number. Usual delivery time is 4-7 workdays.
100% T/T payment before shipment.
You can contact us online or leave us messages below.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews