Send Message
Tel:
Shenzhen Meigaolan Electronic Instrument Co. Ltd
Shenzhen Meigaolan Electronic Instrument Co. Ltd

We will help you achieve your electronic plans.

Any project. Any budget.

Home ProductsMulti Function Calibrator

5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation

5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation

  • 5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation
  • 5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation
  • 5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation
5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation
Product Details:
Place of Origin: USA
Brand Name: Fluke
Certification: FCC
Model Number: 5800A
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: carton
Payment Terms: T/T
Supply Ability: in stock
Contact Now
Detailed Product Description
Product Name: Multi Product Calibrator Amplitude Signals: Up To 600 MHz
Repair Support: Calibration Only Calibration Support: Contact Us
Condition: Pre-Owned Functions: Tested, In Full Working Conditions
High Light:

5800A Multi Function Calibrator

,

Fluke Multi Function Calibrator

,

Automatic Fluke Oscilloscope Calibrator

Fluke 5800A Multi-Product Calibrator

Description of Fluke 5800A Multi Product Calibrator
  • Automatic meter error calculation
  • X and D keys that change the output value to pre-determined cardinal values for various functions
  • Programmable entry limits that prevent invalid amounts from being entered
  • Edge, Leveled Sine, Pulse, Marker, and Wave Generation modes
  • Accurate oscilloscopic input impedance measurement
  • Tunnel Diode Pulse compatibility
  • External reference
  • Auxiliary input
  • 5-channel output (5-channel option). The 5-channel option allows you to calibrate up to five oscilloscope channels simultaneously without changing cables
  • Simultaneous output of a signal and a trigger signal
  • 600 MHz, Leveled Sine wave output
  • Standard IEEE-488 (GPIB) interface, complying with ANSI/IEEE Standards 488.1-1987 and 488.2-1987
  • EIA Standard RS-232-C serial data interface for printing, displaying, or transferring internally stored calibration constants, and for remote control of the 5800A
  • Pass-through RS-232-C serial data interface for communicating with the Unit Under Test (UUT)
  • Extensive automatic internal self testing and diagnostics of analog and digital functions
  • EMC Complies with EN 61326-1
  • Line Power Line Voltage (selectable): 100 V, 120 V, 220 V, 240 V
  • Line Frequency: 47 to 63 Hz
  • Power Consumption 250 VA

The Fluke Model 5800A Oscilloscope Calibrator is a precise instrument that calibrates analog and digital oscilloscopes.

The 5800A Calibrator may be operated at the front panel in the local mode, or remotely using RS-232 or IEEE-488 ports. For remote operations, several software options are available to integrate 5800A operation into a wide variety of calibration requirements.

Fluke 5800A Performance Characteristics

  • Form Factor: Benchtop
  • DC Volts Minimum Range: 6 V
  • DC Volts Maximum Range: 130 V
  • DC Volts No. of Ranges: 2 QTY
  • DC Volts Basic 1 yr accuracy: 0.05 %
  • AC Volts Minimum Range: 6.6 V
  • AC Volts Maximum Range: 130 V
  • AC Volts No. of Ranges: 2 QTY
  • AC Volts Minimum Frequency: 50 kHz
  • AC Volts Maximum Frequency: 600 MHz
  • DC Current Minimum Range: 100 uA
  • DC Current Maximum Range: 100 mA
  • DC Current No. of Ranges: 1 QTY
  • DC Current Basic 1 yr accuracy: 0.05 %
  • AC Current Minimum Range: 100 uA
  • AC Current Maximum Range: 100 mA
  • AC Current Basic 1 Year Accuracy: 0.25 %
  • Resistance Minimum Range: 40 Ohm
  • Resistance Maximum Range: 1.5 MOhm
  • Resistance Basic 1 yr accuracy: 0.1 %
  • Minimum Frequency: 50 Hz
  • Maximum Frequency: 600 MHz
5800A Mainframe Specifications
Voltage DC
Range: 0 to ±6.6V (50Ω)
Range: ±0.25%
  ------------
Range: 0 to ±130V (1 MΩ)
Best 1 Year Specification: ±0.025%
Voltage AC (Squarewave
Range: : 0 to ±6.6V (50Ω)
Best 1 Year Specification: ±0.25%
  --------
Range ±1 mV to ±130V p-p (1 MΩ)
Best 1 Year Specification: ±0.05%
Fast Edge
Range: 4 mV to 2.5V p-p (50Ω)
Best 1 Year Specification: 300 ps Rise Time
Leveled Sinewave
Range: 50 kHz to 600 MHz
Best 1 Year Specification: 50 kHz to 600 MHz
  ±1.5% Flatness
Time Markers
Range: 5s to 500 ps
  Spike, square, 20% pulse, sine
Best 1 Year Specification: ±1 ppm
Wave Generator
Range: Range: 1.8 mV to 55V p-p (1 MΩ)
  1.8 mV to 2.5V p-p (50Ω)
  0.01 Hz to 100 kHz
  Square, Sine, Triangle
Best 1 Year Specification: ±3
Pulse Generator
Range: 15 mV to 1.5V amplitude
Best 1 Year Specification: 1 ns to 500 ns width ±5%
Best 1 Year Specification: 1 ns to 500 ns width ±5%
DC Voltage Measurement
Range: 0 to ±6.6V
Best 1 Year Specification: : ±0.05%
Current DC
Range: ±100 mA to ±100 mA
Best 1 Year Specification: ± 0.25%
Current AC
Range: 100 mA p-p to 100 mA p-p
  10 Hz to 100 kHz
  Squarewave
Best 1 Year Specification: ±0.25%
TV Trigger
  NTSC, SECAM, PAL, PAL-M
Input Impedance Measurement
Range: 40Ω to 1.5 MΩ
Best 1 Year Specification: ±0.1%
  --------
Range: 5 pF to 50 pF
Best 1 Year Specification: ±5%
Overload Measurement
  5V to 9V (dc or ac squarewave), 5 to 60 seconds

 

 

 

List of Options
05 5 CHANNEL OUTPUT

5800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation 05800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation 15800A Fluke Oscilloscope Multi Function Calibrator Automatic Meter Error Calculation 2

 


FAQ:

1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

 

Contact Details
Shenzhen Meigaolan Electronic Instrument Co. Ltd

Contact Person: Jenny

Tel: 86 173 2056 4019

Send your inquiry directly to us
Other Products
Shenzhen Meigaolan Electronic Instrument Co. Ltd
RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Tel:86-755-27883980
Mobile Site Privacy Policy | China Good Quality RF Spectrum Analyzer Supplier. © 2023 - 2024 rf-spectrumanalyzers.com. All Rights Reserved.