| Brand Name: | Fluke |
| Model Number: | 5522A |
| MOQ: | 1 set |
| Price: | Negotiation |
| Payment Terms: | T/T |
The 5522A Multi-Product Calibrator replaces the 5520A and addresses a wide calibration workload with internal and external protection features that prevent damage and facilitate transportation for on-site or mobile calibration. The 5522A can be fully automated with MET/CAL® Plus Calibration Management Software (version 7.3 SP1 or later). It is the ideal calibrator for metrology professionals requiring resistance, voltage, current calibration and more, offering a transportable instrument with high return on investment.
The 5522A functions as a voltage calibrator, resistance calibrator, current calibrator and more. It sources direct voltage and current, alternating voltage and current with multiple waveforms and harmonics, two simultaneous voltage outputs or voltage and current to simulate DC and AC power with phase control, resistance, capacitance, thermocouples and RTDs. The 5522A can also measure thermocouple temperature and pressure using one of 29 Fluke 700 Series pressure modules. Two options add oscilloscope calibration capability to 600 MHz or 1.1 GHz. The 5520A-PQ Power Quality Option enables calibration of power quality instrumentation to IEC and other regulatory standards.
| Direct Volts | 0 to ± 1020 V |
| Direct Current | 0 to 20.5 A |
| Alternating Volts | 1 mV to 1020 V 10 Hz to 500 kHz Volt*Hertz: 1000 V@ 10 kHz/330 V@100 kHz |
| Alternating Current | 29 μA to 20.5 A 10 Hz to 30 kHz |
| Waveforms | Sine, square, triangle, truncated sine |
| Resistance | 0 MΩ to 1100 MΩ |
| Capacitance | 220 pF to 110 mF |
| Power (phantom loads) | 20.9 kW |
| Phase Control | 0.01° |
| Thermocouple (source and measure temperature) | B, C, E, J, K L N R, S, T, U 10 μV/°C |
| RTD (source temperature) | Pt 385-100 Ω, Pt 3926-100 Ω Pt 3916-100 Ω, Pt 385-200 Ω, Pt 385-500 Ω, Pt385 1000 Ω, PtNi 385-120 Ω, (Ni120), Cu 427 10 Ω |
| Interfaces | RS-232, IEEE 488 |
| Phase Lock | Yes |
| Frequency Uncertainty | <2.5 ppm |
| External Frequency Reference (10 MHz) | Yes |
| Calibration Documentation | 17025 accredited report of calibration included |
| Oscilloscope Calibrator (optional) | Levelled sine wave from 5 mV to 5.5 Vpp max, frequencies 50 kHz to 600 kHz and 3.5 Vpp max to 1100 MHz; edge rise times of < 300ps, multiple trigger functions, lowest dc, square wave and timing uncertainty |
| Power Calibrator (optional) | Composite harmonic, flicker simulation, sags and swells simulation modes |
| Model Name | Description |
|---|---|
| 5522A | Multiproduct Calibrator |
| 5522A/6 | Multiproduct Calibrator with 600 MHz Oscilloscope Calibration Option |
| 5522A/1GHZ | Multiproduct Calibrator with 1100 MHz Oscilloscope Calibration Option |
| 5522A-PQ | Multiproduct Calibrator with Power Quality Option |
| 5522A-PQ/6 | Multiproduct Calibrator with Power Quality and 600 MHz Oscilloscope Calibration Options |
| 5522A-PQ/1GHZ | Multiproduct Calibrator with Power Quality and 1100 MHz Oscilloscope Calibration Options |