| Brand Name: | Keysight/Agilent |
| Model Number: | 34470A |
| MOQ: | 1 set |
| Price: | Negotiation |
| Payment Terms: | T/T |
Keysight Agilent 34470A Digital Multimeter 7½ Digit Basic Truevolt
The Keysight 34470A 7½ digit, Performance Truevolt Digital Multimeters offer higher levels of accuracy, speed and resolution.
1. Specifications are for 90-minute warm-up, integration setting of 10 or 100 NPLC, auto-zero on, AC slow filter. ACAL run within the last 2 days.
2. 20% over range on all ranges, except 1000 DCV, 750 ACV, 10 DCA, 3 DCA, 10 ACA, 3 ACA, and diode test have 0%.
3. Relative to calibration standards.
4. The 10 A range is only available on a separate front panel connector. Add 2 mA base per amp for inputs greater than 5 Arms.
5. Add this for each °C outside TCAL ±5°C.
6. Add this for each °C outside the last TACAL ±2°C.
7. Add this for each °C outside TACAL ±2°C.
8. Specifications are for 4-wire ohms function or 2-wire ohms function using math null for offset. Without math null, add 0.2 Ω additional error in 2-wire ohms function. The 100 MΩ and 1 GΩ ranges are 2-wire only. See the manual for low power ohms specification and measurement currents.
9. For each additional volt over ±500 V add 0.02 mV of error.
10. Specifications are for the voltage measured at the input terminals. The 1 mA test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction.
11. See user manual for details.
12. Actual measurement range and probe errors will be limited by the selected probe. Probe accuracy adder includes all measurement and ITS-90 temperature conversion errors. PT100 Ro settable to 100Ω ± 5Ω to remove the initial probe error.
13. The internal reference junction uses the U1180A or equivalent adapter. This has a typical performance of ±1.0°C. This internal reference junction can be adjusted for better accuracy. An external reference junction can also be used.
14. Specifications are for sine wave input > 0.3% of range and > 1 mVrms. 750 ACV range limited to 8 x 107 V.Hz. For each additional volt over 300 Vrms add 1 mVrms of error.
15. Low-frequency performance: three filter settings are available: 3 Hz, 20 Hz, 200 Hz. Frequencies greater than these filter settings are specified with no additional errors.
16. Specifications are for sine wave input > 1% of range and > 10 µArms.
17. Specifications are for sine wave input unless stated otherwise.
18. Square wave input specified for 10 Hz to 300 kHz for 1 second aperture. For shorter apertures, the minimum frequency requires > 2 cycles.
19. Input > 100 mV. For 10 mV to 100 mV inputs, multiply % of reading error x10. Amplitude 10% to 120% of range except 14% to 100% for the 750 ACV range. Specifications are for 1-second gate time (7 digits).
20. Specifications are for using Math Null zeroing. High dissipation factor capacitors may show different results than a single frequency measurement. Film capacitors usually have lower dissipation factors than other dielectrics.
21. The second burden voltage can be obtained by using the 10 A input range.
22. Sample rate (actual): 50.118 kHz (Aperture = 19.953 µs).
23. Thermistor type: 2.2 kΩ (model number 44004), 5 kΩ (model number 44007) and 10 kΩ (model number 44006)
Get more insight quickly: Truevolt DMM's graphical capabilities such as trend and histogram charts offer more insights quickly. Both models also provide a data logging mode for easier trend analysis and a digitizing mode for capturing transients.
Measure low-power devices: The ability to measure very low current, 1 µA range with pA resolution, allows you to make measurements on very low power devices.
Maintain calibrated measurements: Auto calibration allows you to compensate for temperature drift so you can maintain measurement accuracy throughout your workday.
| Option Code | Description |
|---|---|
| 100 | 100-volt ac line selection |
| 120 | 120-volt ac line selection |
| 220 | 220-volt ac line selection |
| 240 | 240-volt ac line selection |
| DIG | Digitizing and Advanced Triggering for 34470A Truevolt DMM license |
| GPB | GPIB interface module for Truevolt series DMMs |
| MEM | 2M Memory for 34470A Truevolt DMM license |
| SEC | NISPOM and file security for Truevolt series DMMs license |
| Z540 | ANSI/NCSL Z540.3-2006 Calibration |
Yes, we can. We send orders worldwide.
We can ship by EMS, DHL, FedEx, UPS, TNT with tracking number. Usual delivery time is 4-7 workdays.
100% T/T payment before shipment.
You can contact us online or leave us messages below.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews