Brand Name: | R&S |
Model Number: | EPL1000 |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | T/T |
R&S Rohde And Schwarz EPL1000 EMI Test Receiver For Compliance Testing
Description of R&S Rohde And Schwarz EPL1000
The R&S®EPL1000 fully complies with CISPR16-1-1. The very fast time domain scan can check the complete CISPR bands A or B in a single shot. Built-in preselection ensures a high dynamic range and enables the acquisition of short pulses. The R&S®EPL1000 offers 4-channel click rate analysis, a real-time spectrogram function, IF analysis and further functions for detailed analysis. Automation simplifies measurements and ensures exact reproducibility of test sequences. These and many more functions make the R&S®EPL1000 ideal for conducted voltage and current measurements. Typical applications include precompliance measurements, precertification and certification in line with IEC, EN, CISPR and FCC.
Key features of EPL1000 EMI Test Receiver
Preselection filters
Time domain scan
Tracking generator
Battery operation
Pulse protected input
▶ EMI detectors: peak, quasi-peak, CISPR-average, RMS-average (CISPR16-1-1)
▶ EMI bandwidth (6 dB)
— 200 Hz, 9 kHz, 120 kHz and 1 MHz (CISPR16-1-1)
— 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz and 1 MHz (MIL-STD-461 and DO-160)
▶ Preselection to increase dynamic range (filters for CISPR band A and B)
— Identify short pulses
— Identify small signals in the presence of strong signals
▶ Transducer factors to include used accessory characteristics (for example cable attenuation or LISN characteristics)
— Simple definition/quick import
— Library covering most of the Rohde&Schwarz accessories
— Record of new transducer factors with integrated tracking generator function (part of R&S®EPL1-B91 internal generator option)
— Selection of one or more
▶ Signal level adaptation to correctly measure strong or weak signals
— Pulse protected input
— Attenuation up to 55 dB in 1 dB steps
— Preamplifier with 20 dB gain
— Autoranging function for automated optimization of the signal adaptation to make maximum use of the dynamic range and to avoid overload within the signal processing chain
▶ Limit line display and checking to easily evaluate measurement results
— Easy definition of limit lines
— Library with more than 170 EMI limit lines based on the latest versions of common EMI standards (CISPR/EN, FCC, MIL-STD-461 and DO-160) for fast and accurate configuration of measurements
▶ Report generation to easily record, document and exchange results
— User-defined layout and content definition through templates
— On-screen display and save of reports (pdf and Word file format
Features & benefits for EPL1000
Automatic measurement of multiple frequency segments with individual settings
The scan table enables the definition of multiple frequency ranges with individual measurement settings. This way, for example, the RBW can be defined individually for CISPR band A and B. Using the configured settings, the R&S®EPL1000 automatically measures all defined frequency ranges sequentially.
Automatic measurement of multiple lines connected to a LISN
Line impedance stabilization networks (LISNs) from Rohde&Schwarz connected to the R&S®EPL1000 with an R&S®EZ-21 control cable can be remotely controlled by the R&S EPL1000, including selection of the line to be measured by the R&S®EPL1000. This function allows all lines connected to a LISN to be measured automatically. On the R&S®EPL1000 GUI, the user simply selects the lines to be measured automatically
Preview and final measurement
The R&S®EPL1000 also supports conventional level determination with only one frequency measured at a time (stepped scan). To reduce the total time, the measurement can be divided into preview and final measurement with peak search. With this method, final measurement is usually performed only for critical frequency points (peaks) using a detector required by the standard with a longer measurement time, allowing the total time to be considerably reduced. Preview measurement, peak search and final measurement with evaluation can be completely automated in the R&S®EPL1000.
List of options for EPL1000
Designation |
Type |
Base unit |
|
EMI test receiver, 5 kHz to 30 MHz |
EPL1000 |
Hardware options |
|
Internal generator, 5 kHz to 30 MHz |
EPL1-B91 |
Replacement SSD, including controller unit |
EPL1-B19 |
OCXO, precision frequency reference |
FPL1-B4 |
GPIB interface |
FPL1-B10 |
DC power supply for 12 V/24 V supply voltage |
FPL1-B30 |
Lithium-ion battery pack, with controller unit for internal battery slot |
FPL1-B31 |
Keycode options |
|
Real-time spectrogram |
EPL1-K55E |
Click rate analyzer |
EPL1-K59 |
IF analysis |
EPL1-K56 |
AM/FM/PM measurement demodulator |
FPL1-K7 |
EMC test software |
|
Essential EMI test software |
ELEMI-E |
License dongle |
EMCPC |
Recommended extras |
|
Protective hard cover |
EPL1-Z1 |
Soft carrying bag, for transport and outdoor operation |
EPL1-Z2 |
H-style shoulder harness (requires FPL1-Z2 option) |
EPL1-Z3 |
Spare lithium-ion battery pack |
FPL1-Z4 |
19" rackmount kit |
EPL1-Z6 |
Lithium-ion battery charger, for charging spare batteries |
FSV-B34 |
Control cable, for ENV216/ENV432/ENV420 |
|
Length: 3 m |
EZ-21 |
Length: 10 m |
EZ-21 |
Calibration |
|
Accredited calibration |
ACAEPL1000 |
Accredited calibration with click rate analyzer (EPL1-K59) |
ACAEPL1000 |
Documentation of calibration values |
DCV-2 |
Printout of DCV |
DCV-ZP |
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .
Brand Name: | R&S |
Model Number: | EPL1000 |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | T/T |
R&S Rohde And Schwarz EPL1000 EMI Test Receiver For Compliance Testing
Description of R&S Rohde And Schwarz EPL1000
The R&S®EPL1000 fully complies with CISPR16-1-1. The very fast time domain scan can check the complete CISPR bands A or B in a single shot. Built-in preselection ensures a high dynamic range and enables the acquisition of short pulses. The R&S®EPL1000 offers 4-channel click rate analysis, a real-time spectrogram function, IF analysis and further functions for detailed analysis. Automation simplifies measurements and ensures exact reproducibility of test sequences. These and many more functions make the R&S®EPL1000 ideal for conducted voltage and current measurements. Typical applications include precompliance measurements, precertification and certification in line with IEC, EN, CISPR and FCC.
Key features of EPL1000 EMI Test Receiver
Preselection filters
Time domain scan
Tracking generator
Battery operation
Pulse protected input
▶ EMI detectors: peak, quasi-peak, CISPR-average, RMS-average (CISPR16-1-1)
▶ EMI bandwidth (6 dB)
— 200 Hz, 9 kHz, 120 kHz and 1 MHz (CISPR16-1-1)
— 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz and 1 MHz (MIL-STD-461 and DO-160)
▶ Preselection to increase dynamic range (filters for CISPR band A and B)
— Identify short pulses
— Identify small signals in the presence of strong signals
▶ Transducer factors to include used accessory characteristics (for example cable attenuation or LISN characteristics)
— Simple definition/quick import
— Library covering most of the Rohde&Schwarz accessories
— Record of new transducer factors with integrated tracking generator function (part of R&S®EPL1-B91 internal generator option)
— Selection of one or more
▶ Signal level adaptation to correctly measure strong or weak signals
— Pulse protected input
— Attenuation up to 55 dB in 1 dB steps
— Preamplifier with 20 dB gain
— Autoranging function for automated optimization of the signal adaptation to make maximum use of the dynamic range and to avoid overload within the signal processing chain
▶ Limit line display and checking to easily evaluate measurement results
— Easy definition of limit lines
— Library with more than 170 EMI limit lines based on the latest versions of common EMI standards (CISPR/EN, FCC, MIL-STD-461 and DO-160) for fast and accurate configuration of measurements
▶ Report generation to easily record, document and exchange results
— User-defined layout and content definition through templates
— On-screen display and save of reports (pdf and Word file format
Features & benefits for EPL1000
Automatic measurement of multiple frequency segments with individual settings
The scan table enables the definition of multiple frequency ranges with individual measurement settings. This way, for example, the RBW can be defined individually for CISPR band A and B. Using the configured settings, the R&S®EPL1000 automatically measures all defined frequency ranges sequentially.
Automatic measurement of multiple lines connected to a LISN
Line impedance stabilization networks (LISNs) from Rohde&Schwarz connected to the R&S®EPL1000 with an R&S®EZ-21 control cable can be remotely controlled by the R&S EPL1000, including selection of the line to be measured by the R&S®EPL1000. This function allows all lines connected to a LISN to be measured automatically. On the R&S®EPL1000 GUI, the user simply selects the lines to be measured automatically
Preview and final measurement
The R&S®EPL1000 also supports conventional level determination with only one frequency measured at a time (stepped scan). To reduce the total time, the measurement can be divided into preview and final measurement with peak search. With this method, final measurement is usually performed only for critical frequency points (peaks) using a detector required by the standard with a longer measurement time, allowing the total time to be considerably reduced. Preview measurement, peak search and final measurement with evaluation can be completely automated in the R&S®EPL1000.
List of options for EPL1000
Designation |
Type |
Base unit |
|
EMI test receiver, 5 kHz to 30 MHz |
EPL1000 |
Hardware options |
|
Internal generator, 5 kHz to 30 MHz |
EPL1-B91 |
Replacement SSD, including controller unit |
EPL1-B19 |
OCXO, precision frequency reference |
FPL1-B4 |
GPIB interface |
FPL1-B10 |
DC power supply for 12 V/24 V supply voltage |
FPL1-B30 |
Lithium-ion battery pack, with controller unit for internal battery slot |
FPL1-B31 |
Keycode options |
|
Real-time spectrogram |
EPL1-K55E |
Click rate analyzer |
EPL1-K59 |
IF analysis |
EPL1-K56 |
AM/FM/PM measurement demodulator |
FPL1-K7 |
EMC test software |
|
Essential EMI test software |
ELEMI-E |
License dongle |
EMCPC |
Recommended extras |
|
Protective hard cover |
EPL1-Z1 |
Soft carrying bag, for transport and outdoor operation |
EPL1-Z2 |
H-style shoulder harness (requires FPL1-Z2 option) |
EPL1-Z3 |
Spare lithium-ion battery pack |
FPL1-Z4 |
19" rackmount kit |
EPL1-Z6 |
Lithium-ion battery charger, for charging spare batteries |
FSV-B34 |
Control cable, for ENV216/ENV432/ENV420 |
|
Length: 3 m |
EZ-21 |
Length: 10 m |
EZ-21 |
Calibration |
|
Accredited calibration |
ACAEPL1000 |
Accredited calibration with click rate analyzer (EPL1-K59) |
ACAEPL1000 |
Documentation of calibration values |
DCV-2 |
Printout of DCV |
DCV-ZP |
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .