Send Message
good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
EMC Test Equipment
Created with Pixso. Agilent Multi Scene MXE EMI Receiver , Extensive Diagnostic Keysight N9038A

Agilent Multi Scene MXE EMI Receiver , Extensive Diagnostic Keysight N9038A

Brand Name: Keysight (Agilent)
Model Number: N9038A
MOQ: 1 set
Price: Negotiation
Payment Terms: T/T
Detail Information
Place of Origin:
Malaysia
Product Name:
MXE EMI Test Receiver
Frequency:
3 Hz To 44 GHz
Resolution Bandwidths:
3 DB
Interface:
USB /1000Base-T LAN/GPIB
Condition:
Pre-Owned
Functions:
Tested, In Full Working Conditions
Supply Ability:
in stock
Highlight:

Agilent MXE EMI Receiver

,

Multi Scene MXE EMI Receiver

,

Keysight N9038A

Product Description
Keysight Agilent N9038A MXE EMI Test Receiver 3 Hz to 44 GHz Extensive Diagnostic
Description of Keysight Agilent N9038A

The Keysight N9038A is a standards-compliant MXE EMI test receiver and diagnostic signal analyzer built on an upgradeable platform. You choose the frequency coverage you need to fully test devices with outstanding accuracy and sensitivity across required ranges.

 

 

Overview and Features of N9038A MXE EMI Test Receiver

  • Perform EMC tests with a standard-compliant receiver: CISPR 16-1-1 & MIL-STD-461
  • Keep the test queue flowing with the accuracy, repeatability and reliability you need to test with confidence
  • Reduce overall scan time with time domain scanning enabled by fast FFT scans
  • Easily identify the frequencies of peak emissions prior to final measurement with monitor spectrum
  • Get enhanced diagnostics using spectrum and real-time analysis, strip chart, markers, span zoom, zoom span, and spectrogram
  • Evaluate emissions and identify suspect signals using EMC measurements through the front panel or remotely with software

Functionality

  • Frequency 20 Hz to 8.4 GHz and 26.5 GHz
  • CISPR, MIL-STD 6 dB, and standard 3 dB resolution bandwidths
  • Quasi-peak, EMI-avg, RMS-avg and diagnostic detectors
  • Extensive diagnostic

Performance

  • Meets CISPR 16-1-1 2010 EMI receiver requirements
  • ±0.75 dB absolute amplitude accuracy
  • -167 dBm displayed average noise level (DANL) with preamplifier and noise floor extension
  • Phase noise -106 dBc/Hz 10 kHz offset

EMC Measurements, Diagnostics & Calibration

  • EMC measurement functionality offering real-time detectors, signal lists, scan tables, limit lines, and correction factors
  • Enhanced analysis with Strip Chart, marker functions, span zoom, zone span, and spectrograms
  • SCPI command language compatibility (included standard)
  • A2LA accredited ISO 17025 calibration available to order

Automation & Communication Interface

  • LXI class C compliant, SCPI and IVI-COM
  • USB 2.0, 1000Base-T LAN, GPIB
  • Common X-Series user interface / Open Windows® XP operating system
List of Options

 

1CM Rack Mount Kit
1CN Front Handle Kit
1CP Rack mount and handle kit
503 3 Hz - 3.6 GHz
508 3 Hz - 8.4 GHz
526 3 Hz- 26.5 GHz
544 3 Hz - 44 GHz
B25 Analysis bandwidth, 25 MHz
B85 Analysis bandwidth, 85 MHz
C35 APC 3.5 mm connector
CNF Type N Connector
CR3 Connector Rear, 2nd IF Output.
DP2 Digital Processor, 2 GB Capture Memory
EXM External Mixing
SS1 Additional removable solid state drive, Win10
WXP Windows Embedded XP
YAS Y-Axis Screen Video Output

 

FAQ:

1.Can you ship order to Canada or Australia ?

Yes,we can .We send orders worldwide .

2. What delivery method do you use ? and delivery time ?

We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

3. What is your payment term?

100% T/T payment before shipment.

4. How can I ask any other question ?

You can contact us online or leave us messages below .

 

 

Agilent Multi Scene MXE EMI Receiver , Extensive Diagnostic Keysight N9038A 0Agilent Multi Scene MXE EMI Receiver , Extensive Diagnostic Keysight N9038A 1

 

 

 

 

 

 

good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
EMC Test Equipment
Created with Pixso. Agilent Multi Scene MXE EMI Receiver , Extensive Diagnostic Keysight N9038A

Agilent Multi Scene MXE EMI Receiver , Extensive Diagnostic Keysight N9038A

Brand Name: Keysight (Agilent)
Model Number: N9038A
MOQ: 1 set
Price: Negotiation
Payment Terms: T/T
Detail Information
Place of Origin:
Malaysia
Brand Name:
Keysight (Agilent)
Model Number:
N9038A
Product Name:
MXE EMI Test Receiver
Frequency:
3 Hz To 44 GHz
Resolution Bandwidths:
3 DB
Interface:
USB /1000Base-T LAN/GPIB
Condition:
Pre-Owned
Functions:
Tested, In Full Working Conditions
Minimum Order Quantity:
1 set
Price:
Negotiation
Payment Terms:
T/T
Supply Ability:
in stock
Highlight:

Agilent MXE EMI Receiver

,

Multi Scene MXE EMI Receiver

,

Keysight N9038A

Product Description
Keysight Agilent N9038A MXE EMI Test Receiver 3 Hz to 44 GHz Extensive Diagnostic
Description of Keysight Agilent N9038A

The Keysight N9038A is a standards-compliant MXE EMI test receiver and diagnostic signal analyzer built on an upgradeable platform. You choose the frequency coverage you need to fully test devices with outstanding accuracy and sensitivity across required ranges.

 

 

Overview and Features of N9038A MXE EMI Test Receiver

  • Perform EMC tests with a standard-compliant receiver: CISPR 16-1-1 & MIL-STD-461
  • Keep the test queue flowing with the accuracy, repeatability and reliability you need to test with confidence
  • Reduce overall scan time with time domain scanning enabled by fast FFT scans
  • Easily identify the frequencies of peak emissions prior to final measurement with monitor spectrum
  • Get enhanced diagnostics using spectrum and real-time analysis, strip chart, markers, span zoom, zoom span, and spectrogram
  • Evaluate emissions and identify suspect signals using EMC measurements through the front panel or remotely with software

Functionality

  • Frequency 20 Hz to 8.4 GHz and 26.5 GHz
  • CISPR, MIL-STD 6 dB, and standard 3 dB resolution bandwidths
  • Quasi-peak, EMI-avg, RMS-avg and diagnostic detectors
  • Extensive diagnostic

Performance

  • Meets CISPR 16-1-1 2010 EMI receiver requirements
  • ±0.75 dB absolute amplitude accuracy
  • -167 dBm displayed average noise level (DANL) with preamplifier and noise floor extension
  • Phase noise -106 dBc/Hz 10 kHz offset

EMC Measurements, Diagnostics & Calibration

  • EMC measurement functionality offering real-time detectors, signal lists, scan tables, limit lines, and correction factors
  • Enhanced analysis with Strip Chart, marker functions, span zoom, zone span, and spectrograms
  • SCPI command language compatibility (included standard)
  • A2LA accredited ISO 17025 calibration available to order

Automation & Communication Interface

  • LXI class C compliant, SCPI and IVI-COM
  • USB 2.0, 1000Base-T LAN, GPIB
  • Common X-Series user interface / Open Windows® XP operating system
List of Options

 

1CM Rack Mount Kit
1CN Front Handle Kit
1CP Rack mount and handle kit
503 3 Hz - 3.6 GHz
508 3 Hz - 8.4 GHz
526 3 Hz- 26.5 GHz
544 3 Hz - 44 GHz
B25 Analysis bandwidth, 25 MHz
B85 Analysis bandwidth, 85 MHz
C35 APC 3.5 mm connector
CNF Type N Connector
CR3 Connector Rear, 2nd IF Output.
DP2 Digital Processor, 2 GB Capture Memory
EXM External Mixing
SS1 Additional removable solid state drive, Win10
WXP Windows Embedded XP
YAS Y-Axis Screen Video Output

 

FAQ:

1.Can you ship order to Canada or Australia ?

Yes,we can .We send orders worldwide .

2. What delivery method do you use ? and delivery time ?

We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

3. What is your payment term?

100% T/T payment before shipment.

4. How can I ask any other question ?

You can contact us online or leave us messages below .

 

 

Agilent Multi Scene MXE EMI Receiver , Extensive Diagnostic Keysight N9038A 0Agilent Multi Scene MXE EMI Receiver , Extensive Diagnostic Keysight N9038A 1