| Brand Name: | Rohde & Schwarz |
| Model Number: | NRPxxT/TN/TWG/TWGN |
| MOQ: | 1 set |
| Price: | Negotiable |
| Delivery Time: | 1~3 Working Days |
| Payment Terms: | T/T,Western Union |
R&S®NRP power meter sensors have long been recognized for supreme precision and speed. R&S®NRPxxT, R&S®NRPxxTN and R&S®NRPxxTWG thermal power sensors are ideal for complex measurement tasks where accuracy is vital. They combine excellent impedance matching with a sophisticated connector concept. The internal calibration test generates reliable and stable measurements. R&S®NRP power meter sensors are available as USB sensors and can also be controlled via LAN. The R&S®NRP power meter portfolio is ideal for production, R&D and calibration labs as well as installation and maintenance.
Thermal power sensors are used in complex measurement tasks where accuracy is vital. To improve measurement accuracy, the R&S®NRPxxT(N)/TWG(N) thermal power sensor hardware is designed to keep measurement noise to a minimum and make the sensor immune to thermal environmental effects. Three times faster than comparable solutions on the market with triggered measurements and > 500 measurements/s in buffered mode.
Measurement uncertainty generally results from mismatches caused by multiple reflections at the source and power sensors. To minimize such reflections, all thermal power sensors in the R&S®NRP family are excellently matched to high frequencies, reducing measurement uncertainty.
The LAN power sensors are ideal for remote monitoring applications such as satellite systems or particle accelerators, where sensors are placed at different points in the system. The LAN interface makes it easy to overcome large distances between the various test points and the control center.
Rohde & Schwarz has implemented a special verification function in R&S®NRPxxT(N) sensors. The function covers all essential signal path components. Using a test routine, sensor response to highly stable applied DC power is measured and compared to the values from the previous calibration. The result provides information about the power sensor functionality and accuracy.
The power sensors come with various detachable cables. The sensor end has a screw connection to prevent accidental loosening of the cable. Direct connections to Rohde & Schwarz signal generators and signal and spectrum analyzers are enhanced with a high-performance power meter. The R&S®NRP-ZKU or R&S®NRP-ZKC USB interface cable can be used to connect a power sensor to a laptop/PC via the USB interface.
| Model | Frequency Range | Level Range | LAN Interface | Connector Type |
|---|---|---|---|---|
| R&S®NRP18T DC - 18 GHz |
-35 dBm - +20 dBm | N(m) | ||
| R&S®NRP18TN DC - 18 GHz |
-35 dBm - +20 dBm | √ | N(m) | |
| R&S®NRP33T DC - 33 GHz |
-35 dBm - +20 dBm | 3.5 mm (m) | ||
| R&S®NRP33TN DC - 33 GHz |
-35 dBm - +20 dBm | √ | 3.5 mm (m) | |
| R&S®NRP40T DC - 40 GHz |
-35 dBm - +20 dBm | 2.92 mm (m) | ||
| R&S®NRP40TN DC - 40 GHz |
-35 dBm - +20 dBm | √ | 2.92 mm (m) | |
| R&S®NRP50T DC - 50 GHz |
-35 dBm - +20 dBm | 2.4 mm (m) | ||
| R&S®NRP50TN DC - 50 GHz |
-35 dBm - +20 dBm | √ | 2.4 mm (m) | |
| R&S®NRP67T DC - 67 GHz |
-35 dBm - +20 dBm | 1.85 mm (m) | ||
| R&S®NRP67TN DC - 67 GHz |
-35 dBm - +20 dBm | √ | 1.85 mm (m) | |
| R&S®NRP90T DC - 90 GHz |
-35 dBm - +20 dBm | 1.35 mm (m) | ||
| R&S®NRP90TN DC - 90 GHz |
-35 dBm - +20 dBm | √ | 1.35 mm (m) | |
| R&S®NRP110T DC - 110 GHz |
-35 dBm - +20 dBm | 1.00 mm (m) | ||
| R&S®NRP75TWG 50 GHz - 75 GHz |
-35 dBm - +20 dBm | WR 15 | ||
| R&S®NRP75TWGN 50 GHz - 75 GHz |
-35 dBm - +20 dBm | √ | WR 15 | |
| R&S®NRP90TWG 60 GHz - 90 GHz |
-35 dBm - +20 dBm | WR 12 | ||
| R&S®NRP90TWGN 60 GHz - 90 GHz |
-35 dBm - +20 dBm | √ | WR 12 | |
| R&S®NRP110TWG 75 GHz - 110 GHz |
-35 dBm - +20 dBm | WR 10 | ||
| R&S®NRP110TWGN 75 GHz - 110 GHz |
-35 dBm - +20 dBm | √ | WR 10 | |
| R&S®NRP140TWG 90 GHz - 140 GHz |
-35 dBm - +20 dBm | WR 8 | ||
| R&S®NRP140TWGN 90 GHz - 140 GHz |
-35 dBm - +20 dBm | √ | WR 8 | |
| R&S®NRP170TWG 110 GHz - 170 GHz |
-35 dBm - +20 dBm | WR 6.5 | ||
| R&S®NRP170TWGN 110 GHz - 170 GHz |
-35 dBm - +20 dBm | √ | WR 6.5 |
| Product | Description |
|---|---|
| R&S®NRP-ZKU USB-A interface cable, length: 0.75 m USB-A interface cable, length: 1.5 m USB-A interface cable, length: 3 m USB-A interface cable, length: 5 m |
|
| R&S®NRP-ZKC USB-C interface cable, length: 0.75 m USB-C interface cable, length: 1.5 m USB-C interface cable, length: 3 m |
|
| R&S®NRP-ZK6 6-pole interface cable, length: 1.5 m 6-pole interface cable, length: 3 m 6-pole interface cable, length: 5 m |
|
| R&S®NRP-ZK8 8-pole interface cable, length: 1.5 m For connection to R&S®NRX 8-pole interface cable, length: 3 m For connection to R&S®NRX 8-pole interface cable, length: 5 m For connection to R&S®NRX |
| Product | Description |
|---|---|
| R&S®NRP-Z5 USB sensor hub R&S®NRP-Z5 can host up to 4 R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors. |
| Product | Description |
|---|---|
| R&S®ZCTW Torque wrench for waveguide flange screws |
|
| R&S®NRP-ZBW Waveguide bracket for R&S®NRP110T |
|
| R&S®WCA75 Waveguide Coax Adapter, WR15 to 1 mm (f) 50 GHz to 75 GHz |
|
| R&S®WCA90 Waveguide Coax Adapter, WR12 to 1 mm (f) 60 GHz to 90 GHz |
|
| R&S®WCA110 Waveguide Coax Adapter, WR10 to 1 mm (f) 75 GHz to 110 GHz |
|
| R&S®WCA12-135 Waveguide Coax Adapter WR12 to 1.35 mm (f) Waveguide Coax Adapter WR12 to 1.35 mm female with S-Parameter characterisation, WG stabilization bracket for USB and LAN NRP power sensors 60 - 90 GHz |
| Product | Description |
|---|---|
| R&S®DCV-1 Documentation of calibration values |
|
| R&S®DCV-ZP Printout of DCV |
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews