Brand Name: | Keysight |
Model Number: | N4691D |
MOQ: | 1 set |
Price: | Negotiable |
Delivery Time: | 1~3 Working Days |
Payment Terms: | T/T,Western Union |
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
The N4691D Option 0DC extends the calibration frequency range down to DC, which is beneficial for broadband device modeling or time domain and signal integrity analysis using enhanced time domain-analysis on the Keysight network analyzers.
This ECal module is an ideal solution for calibrating vector network analyzers. Performing a full two-port calibration takes less than half the time and number of connections versus traditional mechanical cal kits. The operator simply connects the ECal module to the vector network analyzer via USB and the firmware controls the rest, thus reducing the chance for operator error. Wear and tear on connectors is reduced as well, lowering repair costs on both the test port connectors and calibration standards.
Configuration of Keysight N4691D Electronic Calibration Module (ECal)
Options | Descriptions |
Electronic Calibration (ECal) Module | |
N4690D | 18 GHz 2-port type-N 50 ohm ECal module |
N4691D | 26.5 GHz 2-port 3.5 mm ECal module |
N4692D | 40 GHz 2-port 2.92 mm ECal module |
N4693D | 40 GHz 2-port 2.92 mm ECal module |
N4694D | 67 GHz 2-port 1.85 mm ECal module |
N4696D | 18 GHz 2-port 7 mm ECal module |
Frequency options¹ | |
Option 0DC | Starts from DC (for all N469xD models) |
Option 003 | Starts from 300 kHz (for N4690D, N4691D or N4696D) |
Option 100 | Starts from 10 MHz (for N4692D, N4693D or N4694D) |
Connector options2,3 | |
Option F0F | Both connectors are female on module |
Option M0M | Both connectors are male on module |
Option M0F | 1 female and 1 male connector on module |
Calibration options | |
Option 1A7 | Calibration + Uncertainties + Guardbanding (Not Accredited) |
Option A6J | ANSI Z540-1-1994 calibration |
Option UK6 | Commercial calibration certificate test data |
Adapter options (Option 00A)³ | |
N4690D-00A | Add type-N 50 ohm adapters |
N4691D-00A | Add 3.5 mm adapters |
N4692D-00A | Add 2.92 mm adapters |
N4693D-00A | Add 2.4 mm adapters |
N4694D-00A | Add 1.85 mm adapters |
FAQ:
1. Can you ship the order to Canada or Australia?
Yes, we can. We send orders worldwide.
2. What delivery method do you use ? and delivery time?
We can ship by EMS, DHL, FedEx, UPS, and TNT with tracking numbers. The usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question?
You can contact us online or leave us messages below.
Brand Name: | Keysight |
Model Number: | N4691D |
MOQ: | 1 set |
Price: | Negotiable |
Packaging Details: | Carton |
Payment Terms: | T/T,Western Union |
The Keysight N4691D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4691D is a precision 2-port ECal module that supports 3.5 mm connectors up to 26.5 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4691D is included for securing your ECal module and accessories.
The N4691D Option 0DC extends the calibration frequency range down to DC, which is beneficial for broadband device modeling or time domain and signal integrity analysis using enhanced time domain-analysis on the Keysight network analyzers.
This ECal module is an ideal solution for calibrating vector network analyzers. Performing a full two-port calibration takes less than half the time and number of connections versus traditional mechanical cal kits. The operator simply connects the ECal module to the vector network analyzer via USB and the firmware controls the rest, thus reducing the chance for operator error. Wear and tear on connectors is reduced as well, lowering repair costs on both the test port connectors and calibration standards.
Configuration of Keysight N4691D Electronic Calibration Module (ECal)
Options | Descriptions |
Electronic Calibration (ECal) Module | |
N4690D | 18 GHz 2-port type-N 50 ohm ECal module |
N4691D | 26.5 GHz 2-port 3.5 mm ECal module |
N4692D | 40 GHz 2-port 2.92 mm ECal module |
N4693D | 40 GHz 2-port 2.92 mm ECal module |
N4694D | 67 GHz 2-port 1.85 mm ECal module |
N4696D | 18 GHz 2-port 7 mm ECal module |
Frequency options¹ | |
Option 0DC | Starts from DC (for all N469xD models) |
Option 003 | Starts from 300 kHz (for N4690D, N4691D or N4696D) |
Option 100 | Starts from 10 MHz (for N4692D, N4693D or N4694D) |
Connector options2,3 | |
Option F0F | Both connectors are female on module |
Option M0M | Both connectors are male on module |
Option M0F | 1 female and 1 male connector on module |
Calibration options | |
Option 1A7 | Calibration + Uncertainties + Guardbanding (Not Accredited) |
Option A6J | ANSI Z540-1-1994 calibration |
Option UK6 | Commercial calibration certificate test data |
Adapter options (Option 00A)³ | |
N4690D-00A | Add type-N 50 ohm adapters |
N4691D-00A | Add 3.5 mm adapters |
N4692D-00A | Add 2.92 mm adapters |
N4693D-00A | Add 2.4 mm adapters |
N4694D-00A | Add 1.85 mm adapters |
FAQ:
1. Can you ship the order to Canada or Australia?
Yes, we can. We send orders worldwide.
2. What delivery method do you use ? and delivery time?
We can ship by EMS, DHL, FedEx, UPS, and TNT with tracking numbers. The usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question?
You can contact us online or leave us messages below.