| Brand Name: | Tektronix |
| Model Number: | RSA306B |
| MOQ: | 1 set |
| Price: | Negotiable |
| Delivery Time: | 1~3 Working Days |
| Payment Terms: | T/T,Western Union |
The RSA306B uses your PC and Tektronix SignalVu-PC™ RF Signal Analysis Software to provide real time spectrum analysis, streaming capture and deep signal analysis capabilities for signals from 9 kHz to 6.2 GHz, all in a low-cost, highly portable package that is ideal for field, factory, or academic use.
The RSA306B offers full featured spectrum analysis and deep signal analysis at a very attractive price. Using a fast USB3 interface and a user's computer, the RSA306B separates signal acquisition from measurement, dramatically lowering the cost of instrument hardware. The data analysis, storage, and replay is performed on your personal computer, tablet, or laptop. Managing the PC separately from the acquisition hardware makes computer upgrades easy, and minimizes IT management issues.
The RSA306B with SignalVu-PC offers basic and advanced measurements for field and lab. See what you've never seen before: The 40 MHz real time bandwidth of the RSA306B combined with the processing power of SignalVu-PC shows you every signal, even down to 15 μs in duration when a high-performance PC is used. The following image shows a WLAN transmission (green and orange), and the narrow signals that repeat across the screen are a Bluetooth access probe. The spectrogram (upper part of the screen) clearly separates these signals in time to show any signal collisions.
All specifications are guaranteed unless noted otherwise.
| Parameter | Specification |
|---|---|
| RF input frequency range | 9 kHz to 6.2 GHz |
| Parameter | Specification |
|---|---|
| Initial accuracy at calibration | ±3 ppm + aging (after 20 minute warmup at 18 °C to 28 °C ambient) |
| Accuracy, typical | ±20 ppm + aging (after 20 minute warm up at -10 °C to 55 °C ambient) |
| Aging, typical | ± 3 x 10⁻⁶ (1st year), ±1 x 10⁻⁶/year thereafter |
| Parameter | Specification |
|---|---|
| Input frequency range | 10 MHz ±10 Hz |
| Input level range | -10 dBm to +10 dBm sinusoid |
| Impedance | 50 Ω |
| Parameter | Specification |
|---|---|
| Block IQ samples | 1 Hz |
| Streamed ADC samples | 500 kHz |
| Parameter | Specification |
|---|---|
| RF input impedance | 50 Ω |
| RF input VSWR (typical) | ≤ 1.8:1 (10 MHz to 6200 MHz, reference level ≥ +10 dBm) (Equivalent Return Loss: ≥11 dB) |
| Parameter | Specification |
|---|---|
| DC voltage | ±40 VDC |
| Reference level ≥ -10 dBm | +23 dBm (continuous or peak) |
| Reference level < -10 dBm | +15 dBm (continuous or peak) |
The maximum level at the RF input for which the instrument will meet its measurement specifications.
| Parameter | Specification |
|---|---|
| Center frequency < 22 MHz (low-frequency path) | +15 dBm |
| Center frequency ≥22 MHz (RF path) | +20 dBm |