Brand Name: | Keysight (Agilent) |
Model Number: | E8257C |
MOQ: | 1 |
Price: | Negotiation |
Delivery Time: | 1~3 Working Days |
Payment Terms: | Western Union, MoneyGram, T/T |
Keysight (Agilent) E8257C PSG CW and Analog Signal Generator
Description of Keysight (Agilent) E8257C PSG CW and Analog Signal Generator
Low phase noise, high power, and analog modulation
Providing premium performance at an affordable price, the E8257C PSG analog signal generator delivers industry-leading output power, superior level accuracy, low phase noise, and precision analog modulation for accurate characterization of RF and microwave components and devices. It typically eliminates the need of an external amplifier for testing high power devices and minimizes test uncertainty to identify errors early in the design process and reduce development time. The PSG sets a new price performance mark by providing advanced capabilities; including narrow pulses for radar test applications and ramp sweep for continuous sweep measurements and fully automated use with the Agilent 8757D scalar network analyzer.
Modular architecture to meet your test requirements
Customize the PSG for RF and microwave test applications ranging from LO substitution and simple distortion test to general-purpose troubleshooting and transceiver design verification. A variety of optional performance enhancements and accessories are available. Its modular architecture makes it easy to configure the PSG to address your specific test application, providing the level of performance you need today and the option to upgrade in the future.
Features of Keysight (Agilent) E8257C PSG CW and Analog Signal Generator
Form Factor |
---|
Benchtop |
Rackmount ( /1CM /1CP ) |
Plug-In |
Frequency |
---|
250 KHz - 20 GHz ( /520 ) |
31.8 GHz ( /H31 ) |
250 KHz - 40 GHz |
Modulation |
---|
AM ( /UNT ) |
FM ( /H2X ) |
Phase ( /H2X /UNT ) |
Pulse ( /700 ) |
Type |
---|
Analog ( /007 ) |
Microwave |
RF ( /H18 ) |
Digital |
List of Options of Keysight (Agilent) E8257C PSG CW and Analog Signal Generator
007 |
Ramp Analog Sweep |
0BV |
Service Documentation, Component Level |
0BW |
Service Documentation, Assembly Level |
1CM |
Rackmount Kit |
1CN |
Handle Kit |
1CP |
Rackmount and Handle Kit |
1E1 |
Add step attenuator |
1E6 |
Narrow pulse modulation ( 500 MHz-3.2 GHz ) |
1EA |
High RF output power |
1ED |
Type-N RF output connector |
1EM |
Moves all front panel connectors to rear panel |
520 |
250 KHz - 20 GHz |
540 |
250kHz to 40 GHz |
700 |
Standard low band pulse modulation |
724 |
PSG calibration software |
730 |
Chassis combo option for E8257C (UNM+UNP) |
731 |
Chassis combo option for E8257C (UNM+UNR) |
732 |
Chassis combo option for E8257C (1EM+UNP) |
733 |
Chassis combo option for e8257C (1EM+UNR) |
AB1 |
Korea Quick Users Guide (Korean localization) |
AB2 |
China Quick Users Guide (Chinese localization) |
ABA |
U.S. Quick Users Guide (English localization) |
ABD |
Germany Quick Users Guide (German localization) |
ABE |
Spain Quick Users Guide (Spanish localization) |
ABF |
France Quick Users Guide (French localization) |
ABJ |
Japan Quick Users Guide (Japanese localization) |
ABZ |
Italy Quick Users Guide (Italian localization) |
C04 |
Provide special name plate for australian defence force only |
C09 |
Moves all connectors to rear panel except for RF output |
C60 |
Reverse instrument airflow direction (operate environment <=25degC) |
H18 |
Warranted +18 dBm maximum leveled RF output power over 2GHz to 3.2GHz |
H2D |
Unspecified and non-warranted performance for frequencies below 2GHz |
H2X |
Increases maximum deviation by 2 times for FM and phase modulation |
H30 |
Frequency upconversion of RF signals |
H31 |
Limits upper frequency to 31.8 GHz intended for China |
H3P |
Measures integrated phase noise performance |
HB6 |
Prevention of unauthorized firmware upgrade |
HEH |
Improve low band harmonics (10 MHz to 2 GHz) |
HFS |
Provide FM and ramp sweep simultaneously |
HS2 |
Provides sweep time up to 200 seconds for ramp sweep only |
R-51B-001-3C |
1 year Return-to-Agilent warranty extended to 3 years |
R-51B-001-C1 |
1 year Return-to-Agilent warranty |
RMKT |
Agilent Refurbished Product (Do Not Use - Certiprime Option) |
UK6 |
Commercial calibration with test results data |
UN5 |
Standard output power |
UNC |
Standard connector ( 3.5 mm ) |
UNM |
Standard Front and Rear Panel Connector Configuration |
UNN |
No step attenuator |
UNP |
Standard spectral purity |
UNR |
Enhanced phase noise |
UNT |
AM/FM/Phase Modulation and LF Output |
Our service:
One-stop service from manufacture to shipping.
1. Your inquiry related to our products or prices will be replied in 24hours.
2. Well-trained and experienced staffs to answer all your enquires influent English.
3. Distributor ship is offered for your unique desigh and some our current models.
4. Protection of your sales area, ideas of design and all your private information.
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below.
Brand Name: | Keysight (Agilent) |
Model Number: | E8257C |
MOQ: | 1 |
Price: | Negotiation |
Packaging Details: | Carton |
Payment Terms: | Western Union, MoneyGram, T/T |
Keysight (Agilent) E8257C PSG CW and Analog Signal Generator
Description of Keysight (Agilent) E8257C PSG CW and Analog Signal Generator
Low phase noise, high power, and analog modulation
Providing premium performance at an affordable price, the E8257C PSG analog signal generator delivers industry-leading output power, superior level accuracy, low phase noise, and precision analog modulation for accurate characterization of RF and microwave components and devices. It typically eliminates the need of an external amplifier for testing high power devices and minimizes test uncertainty to identify errors early in the design process and reduce development time. The PSG sets a new price performance mark by providing advanced capabilities; including narrow pulses for radar test applications and ramp sweep for continuous sweep measurements and fully automated use with the Agilent 8757D scalar network analyzer.
Modular architecture to meet your test requirements
Customize the PSG for RF and microwave test applications ranging from LO substitution and simple distortion test to general-purpose troubleshooting and transceiver design verification. A variety of optional performance enhancements and accessories are available. Its modular architecture makes it easy to configure the PSG to address your specific test application, providing the level of performance you need today and the option to upgrade in the future.
Features of Keysight (Agilent) E8257C PSG CW and Analog Signal Generator
Form Factor |
---|
Benchtop |
Rackmount ( /1CM /1CP ) |
Plug-In |
Frequency |
---|
250 KHz - 20 GHz ( /520 ) |
31.8 GHz ( /H31 ) |
250 KHz - 40 GHz |
Modulation |
---|
AM ( /UNT ) |
FM ( /H2X ) |
Phase ( /H2X /UNT ) |
Pulse ( /700 ) |
Type |
---|
Analog ( /007 ) |
Microwave |
RF ( /H18 ) |
Digital |
List of Options of Keysight (Agilent) E8257C PSG CW and Analog Signal Generator
007 |
Ramp Analog Sweep |
0BV |
Service Documentation, Component Level |
0BW |
Service Documentation, Assembly Level |
1CM |
Rackmount Kit |
1CN |
Handle Kit |
1CP |
Rackmount and Handle Kit |
1E1 |
Add step attenuator |
1E6 |
Narrow pulse modulation ( 500 MHz-3.2 GHz ) |
1EA |
High RF output power |
1ED |
Type-N RF output connector |
1EM |
Moves all front panel connectors to rear panel |
520 |
250 KHz - 20 GHz |
540 |
250kHz to 40 GHz |
700 |
Standard low band pulse modulation |
724 |
PSG calibration software |
730 |
Chassis combo option for E8257C (UNM+UNP) |
731 |
Chassis combo option for E8257C (UNM+UNR) |
732 |
Chassis combo option for E8257C (1EM+UNP) |
733 |
Chassis combo option for e8257C (1EM+UNR) |
AB1 |
Korea Quick Users Guide (Korean localization) |
AB2 |
China Quick Users Guide (Chinese localization) |
ABA |
U.S. Quick Users Guide (English localization) |
ABD |
Germany Quick Users Guide (German localization) |
ABE |
Spain Quick Users Guide (Spanish localization) |
ABF |
France Quick Users Guide (French localization) |
ABJ |
Japan Quick Users Guide (Japanese localization) |
ABZ |
Italy Quick Users Guide (Italian localization) |
C04 |
Provide special name plate for australian defence force only |
C09 |
Moves all connectors to rear panel except for RF output |
C60 |
Reverse instrument airflow direction (operate environment <=25degC) |
H18 |
Warranted +18 dBm maximum leveled RF output power over 2GHz to 3.2GHz |
H2D |
Unspecified and non-warranted performance for frequencies below 2GHz |
H2X |
Increases maximum deviation by 2 times for FM and phase modulation |
H30 |
Frequency upconversion of RF signals |
H31 |
Limits upper frequency to 31.8 GHz intended for China |
H3P |
Measures integrated phase noise performance |
HB6 |
Prevention of unauthorized firmware upgrade |
HEH |
Improve low band harmonics (10 MHz to 2 GHz) |
HFS |
Provide FM and ramp sweep simultaneously |
HS2 |
Provides sweep time up to 200 seconds for ramp sweep only |
R-51B-001-3C |
1 year Return-to-Agilent warranty extended to 3 years |
R-51B-001-C1 |
1 year Return-to-Agilent warranty |
RMKT |
Agilent Refurbished Product (Do Not Use - Certiprime Option) |
UK6 |
Commercial calibration with test results data |
UN5 |
Standard output power |
UNC |
Standard connector ( 3.5 mm ) |
UNM |
Standard Front and Rear Panel Connector Configuration |
UNN |
No step attenuator |
UNP |
Standard spectral purity |
UNR |
Enhanced phase noise |
UNT |
AM/FM/Phase Modulation and LF Output |
Our service:
One-stop service from manufacture to shipping.
1. Your inquiry related to our products or prices will be replied in 24hours.
2. Well-trained and experienced staffs to answer all your enquires influent English.
3. Distributor ship is offered for your unique desigh and some our current models.
4. Protection of your sales area, ideas of design and all your private information.
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below.