We will help you achieve your electronic plans.
Any project. Any budget.
Place of Origin: | Germany |
Brand Name: | R&S |
Model Number: | SMU200A |
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiation |
Payment Terms: | T/T |
Supply Ability: | in stock |
Product Name: | Vector Signal Generator | Form Factor: | Benchtop/Portable/Rackmount |
---|---|---|---|
Modulation: | FM/IF/Phase/Pulse/Scan | Type: | Analog/Digital/RF |
Condition: | Pre-Owned | Functions: | Tested, In Full Working Conditions |
Highlight: | Portable RF Frequency Generator,Digital RF Frequency Generator,SMU200A |
R&S Rohde And Schwarz SMU200A Vector Signal Generator 100 KHz To 6 GHz
Description of R&S SMU200A
The new Vector Signal Generator from Rohde and Schwarz SMU200A is designed to meet all requirements encountered in research and of modern communication systems as well as in their production. The Rohde and Schwarz SMU200A not only combines up to two independent signal generators in one cabinet of only four height units, it also offers unrivalled RF and baseband characteristics. The modern, intuitive concept of the R&S SMU200A ensures fast and easy operation.
Key features of SMU200A Vector Signal Generator
• Two signal generators in one
• Frequency options from 100 kHz to 2.2/3/4/6 GHz for the first RF path
• Optional second RF path up to 2.2 GHz or 3 GHz • Up to two complete baseband paths
• Lossless combination of baseband signals in the digital domain (e.g. for testing multistandard base stations)
B10 | External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of |
B102 | 100 KHz - 2.2 GHz |
B103 | 100 KHz - 3 GHz |
B104 | 100 KHz - 4 GHz |
B105 | 100 KHz - 6 GHz |
B11 | Baseband Generator with ARB (64 Msample) and Digital Modulation (realtime |
B12 | Output attenuator for tracking generator |
B13 | Baseband Main Module |
B14 | Fading Simulator |
B15 | Fading Simulator Extension |
B16 | Differential I/Q Output |
B17 | Analog Baseband Input |
B18 | Removable Hard Disk (Flash Card) for R&S® ESU |
B19 | Second Hard Disk (Flash Card) for R&S® ESU-B18 |
B20 | FM/ Ø Modulation |
B202 | RF Path B 100 KHz - 2.2 GHz |
B203 | RF Path B 100 KHz - 3 GHz |
B22 | FM/ Ø Modulation w/ Enhanced Phase Noise Performance |
B24 | Internal preamplifier 100kHz to 40GHz; gain 30dB nominal (For EMI Test Receiver R&S® ESU40; |
B30 | Overvoltage Protection |
B31 | High Output Power |
B32 | Overvoltage Protection and High Output Power |
B35 | RF Path B Overvoltage Protection |
B36 | RF Path B High Output Power |
B37 | RF Path B Overvoltage Protection and High Output Power |
B4 | OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR |
B9 | Baseband Generator with ARB (128 Msample) and Digital Modulation (realtime |
C3 | Three years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s). |
C5 | Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s). |
DCV-2 | Documentation of calibration values |
DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
DKD | ESU40 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
ESPIK50 | Trigger for coverage measurements with EMI Test Receivers R&S ESPI and R&S ESU |
ESU26-DKD | ESU26 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
ESU8-DKD | ESU8 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
FS-K7 | FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU) |
FSP-B10 | External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of |
FSU-B12 | Output attenuator for tracking generator for FSU, FSQ |
FSU-B4 | OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR |
FSU-B9 | Tracking generator for FSU and FSQ, 100 kHz - 3.6 GHz |
K11 | Dig. Std. IS-95 |
K12 | Dig. Std. cdma2000 |
K40 | Digital standard GSM/EDGE, 1160.7609.02 |
K42 | Dig. Std. 3GPP FDD |
K43 | Dig. Std. 3GPP Enh. BS/MS Test incl. HSDPA |
K47 | Dig. Std. 1xEV-DO |
K53 | Time Domain Scan FFT based scan for very fast overview measurements |
K55 | Dig. Std. E-UTRA |
K7 | FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU) |
R3 | Three years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
R5 | Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty. |
FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .
Contact Person: Dannie
Tel: +8613728348365