| Brand Name: | Keysight Agilent |
| Model Number: | N5244A |
| MOQ: | 1 set |
| Price: | Negotiable |
| Delivery Time: | 1~3 working days |
| Payment Terms: | T/T,Western Union, MoneyGram |
The Radio Frequency Spectrum Analyzer is a powerful tool for measuring and analyzing radio frequencies, ideal for applications in product development, wireless communications, and more. With an amplitude range of -140 dBm to +20 dBm, it can detect signals from 10 MHz to 43.5 GHz.
This Wireless Frequency Analyzer provides various measurements (peak, average, and quasi-peak), trigger modes (free run, external, video, pulse, and timeout), and advanced spectrum analyzer software. It's ideal for testing wireless systems, antennas, and receivers, as well as measuring and monitoring interference from other signals.
Whether you are a professional engineer or an amateur radio enthusiast, this analyzer delivers reliable and accurate results across a wide frequency range, making it suitable for applications from wireless communication to broadcast and satellite communications.
The Keysight Agilent N5244A RF Spectrum Analyzer is perfect for analyzing frequency signals in various applications. This instrument features multiple display modes including Normal, Max Hold, and Average, along with comprehensive trigger modes. With impressive accuracy, resolution bandwidth from 1 Hz to 1 MHz, and convenient desktop size, it's ideal for spectrum frequency analysis, radio frequency analysis, and wireless frequency analysis.
| Code | Description |
|---|---|
| 008 | Pulsed-RF Measurements |
| 010 | Time-domain measurements |
| 020 | Add IF inputs |
| 021 | Add pulse modulator to internal first source |
| 022 | Add pulse modulator to internal second source |
| 025 | Add four internal pulse generators |
| 028 | Noise figure measurements using standard receivers |
| 080 | Frequency offset measurements |
| 081 | Reference Channel Switch (Adds internal switch to R1 Path)(Standard Option w/080) |
| 082 | Scalar calibrated converter measurements |
| 083 | Vector and scalar calibrated converter measurements |
| 084 | Embedded LO measurements |
| 086 | Gain compression measurements |
| 087 | Intermodulation distortion measurements |
| 088 | Source phase control |
| 118 | Fast CW mode |
| 1A7 | ISO 17025 compliant calibration |
| 1CM | Rack mount kit for installation without handles |
| 1CP | Rack mount kit for installation with handles |
| 200 | 2 ports, single source |
| 219 | Add extended power range and bias-tees to 2 port analyzer |
| 224 | Add internal second source, combiner and mechanical switches to 2-port analyzer |
| 29 | Corrected noise figure measurements |
| 301 | Application for use with standard CalPods |
| 302 | Application for use with temperature-characterized CalPods |
| 400 | 4 ports, dual source |
| 417 | 4-port dual source extended power range |
| 419 | Add extended power range and bias-tees to 4 port analyzer |
| 423 | Add internal combiner and mechanical switches to 4-port analyzer |
| 460 | Integrated true-mode stimulus application |
| 510 | Nonlinear component characterization |
| 514 | Nonlinear x-parameters |
| 518 | Nonlinear pulse envelope domain |
| 520 | Arbitrary load impedance X-parameters |
| 551 | N-port calibrated measurements |
| 897 | Built-in performance test software for Agilent inclusive calibration, perpetual license |
| 898 | Built-in performance test software for standards compliant calibration, perpetual license |
| A6J | ANSI Z540 compliant calibration |
| H85 | Removes bias tees between source attenuators and test port couplers |
| N1966A | Pulse/IO Adapter |
| N8981A | Spare hard drive for use with 1.1 GHz Pentium M CPU board Recommended for use in secure environments |
| PS-S10 | Remote scheduled productivity assistance. Select 1 to 999 hours. |
| PS-S20 | Startup assistance |
| PS-S20-01 | Recommended Startup assistance |
| PS-T10-PNA | PNA operator training for 8 students at the customer's site , H7215B-203 |
| PS-T12-PNA | PNA programming for 8 students at the customer's site , H7215B-204 |
| R-50C-011-3 | Agilent Calibration - 3 years |
| R-50C-011-5 | Agilent Calibration - 5 years |
| R-50C-016-3 | ISO 17025 Compliant Calibration - 3 years |
| R-50C-016-5 | ISO 17025 Compliant Calibration - 5 years |
| R-50C-021-3 | ANSI Z540-1-1994 Calibration - 3 years |
| R-50C-021-5 | ANSI Z540-1-1994 Calibration - 5 years |
| R-50J-001-3 | Onsite System Verification - 3 years |
| R-50U-001-3 | Onsite Agilent Calibration - 3 years |
| R-50U-002-3 | Onsite ANSI Z540-1-1994 Calibration - 3 years |
| R-51B-001-3C | Return to Agilent Warranty - 3 years |
| R-51B-001-5C | Return to Agilent Warranty - 5 years |
| R-51B-001-C | Return to Agilent Warranty - 1 year |
| R-51C-001-1CU | Onsite Warranty - 1 year |
| R-51C-001-3CU | Onsite Warranty - 3 years |
| UK6 | Commercial calibration certificate with test data |
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews