Brand Name: | Keysight/Agilent |
Model Number: | E4448A |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | T/T |
Keysight Agilent E4448A PSA Spectrum Analyzer 3 Hz to 50 GHz
The Agilent E4448A PSA high-performance spectrum analyzer measures and monitors complex RF, microwave, and millimeter-wave signals up to 50 GHz. With optional external mixing, the frequency coverage expands to 110 GHz with the Agilent external mixer, and to 325 GHz with other vendors'' mixers. Agilent external mixer offerings.
Frequency Range: The E4448A typically covers a wide frequency range, from a few Hz to 50 GHz or higher, depending on the model and options chosen. This broad frequency coverage makes it suitable for a wide range of RF and microwave measurement tasks.
Frequency Resolution Bandwidth (RBW): It offers selectable RBW options, allowing users to adjust the resolution bandwidth according to their measurement requirements. This feature enables fine frequency resolution for detailed spectral analysis.
Dynamic Range: The spectrum analyzer provides a high dynamic range, allowing it to capture and analyze both weak and strong signals accurately. This capability is essential for detecting and characterizing signals in various environments.
Sensitivity: It offers excellent sensitivity, enabling the detection and analysis of low-level signals with high accuracy. This sensitivity is crucial for applications where the signals of interest are weak or buried in noise.
Measurement Speed: The E4448A is known for its fast measurement speed, allowing users to quickly capture and analyze signals in real-time. This rapid measurement capability is beneficial for applications requiring quick signal analysis and troubleshooting.
Display and User Interface: It features a high-resolution display and an intuitive user interface, making it easy for users to navigate menus, configure settings, and interpret measurement results. The user-friendly interface enhances productivity and reduces the learning curve for new users.
Advanced Analysis Capabilities: The spectrum analyzer may include advanced analysis functions such as channel power, adjacent channel power ratio (ACPR), occupied bandwidth (OBW), and phase noise measurements. These capabilities enable in-depth signal characterization and modulation analysis.
Remote Control and Connectivity: It supports remote control via various interfaces such as LAN (Local Area Network), USB (Universal Serial Bus), and GPIB (General Purpose Interface Bus). This remote control capability allows for easy integration into automated test systems and remote operation.
Overall, the Keysight Agilent E4448A spectrum analyzer is a versatile and high-performance instrument suitable for a wide range of RF and microwave measurement tasks, including research, development, manufacturing, and maintenance in industries such as telecommunications, aerospace, defense, and wireless communications.
Migration from PSA to PXA:
The PXA N9030A, Agilent’s next-generation high-performance signal analyzer, combines the PSA’s technical excellence with state-of-the-art technologies, making it a logical form-fit-functional replacement for the PSA. The new PXA N9030A offers greater performance, wider analysis bandwidth, and more powerful connectivity.
List of Options
000 | E4448A PSA Spectrum Analyzer, 3 Hz - 50 GHz |
015 | 6 GHz return-loss Measurement Accessory Kit |
033 | Measuring receiver connector accessory kit |
045 | Millimeter Wave Accessory |
071 | Digital Demodulation H/W for S/N USUS4142/MY4140 Changed ot B7J on newer models |
0B0 | Do not include manuals |
0B1 | Add Manual Set |
0BV | Service Documentation, Component Level |
0BW | Service Documentation, Assembly Level |
107 | Audio input 100 kOhm |
110 | RF/uW internal preamplifier |
111 | USB device side I/O interface |
115 | 512 MB user memory |
117 | Secure memory erase |
119 | Noise Figure Hardware Kit . Standard on all models S/N > US4222/MY4100. |
122 | 80 MHz bandwidth digitizer |
123 | Switchable MW Preselector Bypass |
124 | Y-axis video output |
140 | 40 MHz bandwidth digitizer |
1A7 | PSA Series ISO 17025 compliant calibration with test data |
1CM | Rackmount Kit |
1CN | Handle kit |
1CP | Rack mount kit with handles |
1CR | Rack slide kit |
1DS | RF internal preamplifier |
202 | GSM w/EDGE Measurement Personality |
204 | 1xEV-DO Measurement Personality |
210 | HSDPA/HSUPA measurement personality |
211 | TD-SCDMA measurement personality |
212 | TD-SCDMA Modulation Analysis Measurement Personality |
213 | HSPA/8PSK for TD-SCDMA Modulation Analysis Measurement Personality |
214 | 1xEV-DV measurement personality |
215 | External Source Control Measurement Personality |
217 | WLAN Measurement Personality |
219 | Noise figure measurement personality |
226 | Phase noise measurement personality |
230 | Benchlink web remote control software |
233 | Built-in measuring receiver personality |
235 | Wide BW digitizer external cal wizard |
239 | EMC measurement personality |
23A | AM/FM/PM triggering for measuring receiver |
23B | CCITT filter for audio measurements |
241 | Flexible digital modulation analysis |
266 | Programming code compatibility suite measurement personality |
423 | Switchable Microwave Preselector Bypass. Available for all models with S/N |
426 | Gated Sweep Hardware. Standard on all models >S/N US/MY4336. |
516 | 40 MHz BW IF output - low band |
517 | Boris DIF --with opt 122 or 124 |
518 | Natasha DIF -- no opt 122 or 124 |
520 | Preselector bias cable - no opt HNQ |
627 | Required for all options except HT1 |
628 | Required for all options except 111 |
629 | Required for 110 or 123 or 110 with 123 |
630 | Required for option 110 without 123 |
631 | Required for 123 without 110 |
632 | Required for option 110 with 123 |
633 | Required for all options except HS1, HS7 and HT1 |
903 | 120V POWER CORD, USA & CANADA |
A6J | PSA Series ANSI Z540 compliant calibration with test data |
AB1 | Korea Quick Users Guide (Korean localization) |
AB2 | China Quick Users Guide (Chinese localization) |
ABA | U.S. Quick Users Guide (English localization) |
ABD | Germany Quick Users Guide (German localization) |
ABE | Spain Quick Users Guide (Spanish localization) |
ABF | France Quick Users Guide (French localization) |
ABJ | Japan Quick Users Guide (Japanese localization) |
ABZ | Italy Quick Users Guide (Italian localization) |
ANE | 64 MB Flash Ram Memory. Shipped Standard on all 46A/47A/48A Models. Shipped Standard on all models >US/MY4222 |
ATP04 | ATP LEADTIME ITEM FOR E4448A-H7L |
ATP05 | ATP LEADTIME ITEM FOR E4448A-HB2 |
ATP06 | ATP LEADTIME ITEM FOR E4448A-HGT |
ATP07 | ATP LEADTIME ITEM FOR E4448A-HN9 |
ATP08 | ATP LEADTIME ITEM FOR E4448A-JMP |
AYZ | External mixing |
B78 | CDMA2000 Measurement Personality |
B7J | Digital Demodulation Hardware |
BAB | 3.5 mm RF input connector |
BAC | CDMAOne Measurement Personality |
BAE | NADC,PDC Measurement Personality |
BAF | W-CDMA Measurement Personality |
C01 | RF connector color code |
H25 | 25 MHz IF Output |
H26 | High Band Preamplifier (Discontiued) Replaced by option 110. |
H70 | 70 MHz IF Output |
H7L | Auxiliary Wideband Log Video Output |
HB2 | 21.4 MHz IF Output |
HB6 | Prevention of unauthorized FW upgrade |
HBA | Rear Panel RF Input |
HGT | Allows Gate width of less than 10 uSec. |
HN8 | Wideband Preselector Bypass (No Preselector) |
HN9 | 80 MHz wide baseband IF output at 321.4 MHz for frequencies less than 3.05 GHz |
HNQ | I/Q Front Panel Output connectors with hardware for use with 89600A. |
HS1 | Increase level of security write protects to user files |
HS7 | Security erase software |
HT1 | GPS Interface Card for Trimble GPS |
HV5 | Y-AXIS VIDEO OUTPUT modified to 856x output level |
HY3 | Combine Option 123 and AYZ |
HY7 | Improved Gain 70 MHz IF Output |
HYX | 21.4 MHz IF Rear Panel Output |
JMP | Rear panel jumper cable |
N6171A | MATLAB Software |
N6171A-M01 | MATLAB - Basic Package |
N6171A-M02 | MATLAB - Standard Package |
N6171A-M03 | MATLAB - Advanced Package |
N9051A | Pulse measurement software |
N9051A-2FP | Pulse measurement software, fixed, perpetual, license |
N9051A-3FP | Phase & Frequency Measurements |
N9051A-4FP | Extended Analysis & Statistics |
PS-S20-01 | Recommended Startup assistance |
R-50C-001 | Standard Calibration w/data. Replaced UK6 |
R-50C-002 | Traceable Calibration standards compliant initial receipt. (ANSI-Z540/17025) |
R-50C-011-3 | Agilent Calibration - 3 years |
R-50C-011-5 | Agilent Calibration - 5 years |
R-50C-016-3 | ISO 17025 Compliant Calibration - 3 years |
R-50C-016-5 | ISO 17025 Compliant Calibration - 5 years |
R-50C-021-3 | ANSI Z540-1-1994 Calibration - 3 years |
R-50C-021-5 | ANSI Z540-1-1994 Calibration - 5 years |
R-50G-521 | Z540 CALIBRATION |
R-51B-001-3C | Return to Agilent Warranty - 3 years |
R-51B-001-5C | Return to Agilent Warranty - 5 years |
R-51B-001-C | Return to Agilent Warranty - 1 year |
R-52A-001-3 | 3 Year Calibration License (Commercial) |
R-52A-001-L | Lifetime Calibration License (Commercial) |
R-52A-002-3 | 3 Year Calibration License (Z540/17025) |
R-52A-002-L | Lifetime Calibration License (Z540/17025) |
RMKT | Agilent Refurbished Product (Do Not Use - Certiprime Option) |
UE2 | Firmware Kit. CD-ROM. |
UK6 | Commercial Cal Certificate with Data |
FAQ:
1.Can you ship order to Canada or Australia?
Yes,we can .We send orders worldwide.
2. What delivery method do you use? and delivery time?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question?
You can contact us online or leave us messages below.
Brand Name: | Keysight/Agilent |
Model Number: | E4448A |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | T/T |
Keysight Agilent E4448A PSA Spectrum Analyzer 3 Hz to 50 GHz
The Agilent E4448A PSA high-performance spectrum analyzer measures and monitors complex RF, microwave, and millimeter-wave signals up to 50 GHz. With optional external mixing, the frequency coverage expands to 110 GHz with the Agilent external mixer, and to 325 GHz with other vendors'' mixers. Agilent external mixer offerings.
Frequency Range: The E4448A typically covers a wide frequency range, from a few Hz to 50 GHz or higher, depending on the model and options chosen. This broad frequency coverage makes it suitable for a wide range of RF and microwave measurement tasks.
Frequency Resolution Bandwidth (RBW): It offers selectable RBW options, allowing users to adjust the resolution bandwidth according to their measurement requirements. This feature enables fine frequency resolution for detailed spectral analysis.
Dynamic Range: The spectrum analyzer provides a high dynamic range, allowing it to capture and analyze both weak and strong signals accurately. This capability is essential for detecting and characterizing signals in various environments.
Sensitivity: It offers excellent sensitivity, enabling the detection and analysis of low-level signals with high accuracy. This sensitivity is crucial for applications where the signals of interest are weak or buried in noise.
Measurement Speed: The E4448A is known for its fast measurement speed, allowing users to quickly capture and analyze signals in real-time. This rapid measurement capability is beneficial for applications requiring quick signal analysis and troubleshooting.
Display and User Interface: It features a high-resolution display and an intuitive user interface, making it easy for users to navigate menus, configure settings, and interpret measurement results. The user-friendly interface enhances productivity and reduces the learning curve for new users.
Advanced Analysis Capabilities: The spectrum analyzer may include advanced analysis functions such as channel power, adjacent channel power ratio (ACPR), occupied bandwidth (OBW), and phase noise measurements. These capabilities enable in-depth signal characterization and modulation analysis.
Remote Control and Connectivity: It supports remote control via various interfaces such as LAN (Local Area Network), USB (Universal Serial Bus), and GPIB (General Purpose Interface Bus). This remote control capability allows for easy integration into automated test systems and remote operation.
Overall, the Keysight Agilent E4448A spectrum analyzer is a versatile and high-performance instrument suitable for a wide range of RF and microwave measurement tasks, including research, development, manufacturing, and maintenance in industries such as telecommunications, aerospace, defense, and wireless communications.
Migration from PSA to PXA:
The PXA N9030A, Agilent’s next-generation high-performance signal analyzer, combines the PSA’s technical excellence with state-of-the-art technologies, making it a logical form-fit-functional replacement for the PSA. The new PXA N9030A offers greater performance, wider analysis bandwidth, and more powerful connectivity.
List of Options
000 | E4448A PSA Spectrum Analyzer, 3 Hz - 50 GHz |
015 | 6 GHz return-loss Measurement Accessory Kit |
033 | Measuring receiver connector accessory kit |
045 | Millimeter Wave Accessory |
071 | Digital Demodulation H/W for S/N USUS4142/MY4140 Changed ot B7J on newer models |
0B0 | Do not include manuals |
0B1 | Add Manual Set |
0BV | Service Documentation, Component Level |
0BW | Service Documentation, Assembly Level |
107 | Audio input 100 kOhm |
110 | RF/uW internal preamplifier |
111 | USB device side I/O interface |
115 | 512 MB user memory |
117 | Secure memory erase |
119 | Noise Figure Hardware Kit . Standard on all models S/N > US4222/MY4100. |
122 | 80 MHz bandwidth digitizer |
123 | Switchable MW Preselector Bypass |
124 | Y-axis video output |
140 | 40 MHz bandwidth digitizer |
1A7 | PSA Series ISO 17025 compliant calibration with test data |
1CM | Rackmount Kit |
1CN | Handle kit |
1CP | Rack mount kit with handles |
1CR | Rack slide kit |
1DS | RF internal preamplifier |
202 | GSM w/EDGE Measurement Personality |
204 | 1xEV-DO Measurement Personality |
210 | HSDPA/HSUPA measurement personality |
211 | TD-SCDMA measurement personality |
212 | TD-SCDMA Modulation Analysis Measurement Personality |
213 | HSPA/8PSK for TD-SCDMA Modulation Analysis Measurement Personality |
214 | 1xEV-DV measurement personality |
215 | External Source Control Measurement Personality |
217 | WLAN Measurement Personality |
219 | Noise figure measurement personality |
226 | Phase noise measurement personality |
230 | Benchlink web remote control software |
233 | Built-in measuring receiver personality |
235 | Wide BW digitizer external cal wizard |
239 | EMC measurement personality |
23A | AM/FM/PM triggering for measuring receiver |
23B | CCITT filter for audio measurements |
241 | Flexible digital modulation analysis |
266 | Programming code compatibility suite measurement personality |
423 | Switchable Microwave Preselector Bypass. Available for all models with S/N |
426 | Gated Sweep Hardware. Standard on all models >S/N US/MY4336. |
516 | 40 MHz BW IF output - low band |
517 | Boris DIF --with opt 122 or 124 |
518 | Natasha DIF -- no opt 122 or 124 |
520 | Preselector bias cable - no opt HNQ |
627 | Required for all options except HT1 |
628 | Required for all options except 111 |
629 | Required for 110 or 123 or 110 with 123 |
630 | Required for option 110 without 123 |
631 | Required for 123 without 110 |
632 | Required for option 110 with 123 |
633 | Required for all options except HS1, HS7 and HT1 |
903 | 120V POWER CORD, USA & CANADA |
A6J | PSA Series ANSI Z540 compliant calibration with test data |
AB1 | Korea Quick Users Guide (Korean localization) |
AB2 | China Quick Users Guide (Chinese localization) |
ABA | U.S. Quick Users Guide (English localization) |
ABD | Germany Quick Users Guide (German localization) |
ABE | Spain Quick Users Guide (Spanish localization) |
ABF | France Quick Users Guide (French localization) |
ABJ | Japan Quick Users Guide (Japanese localization) |
ABZ | Italy Quick Users Guide (Italian localization) |
ANE | 64 MB Flash Ram Memory. Shipped Standard on all 46A/47A/48A Models. Shipped Standard on all models >US/MY4222 |
ATP04 | ATP LEADTIME ITEM FOR E4448A-H7L |
ATP05 | ATP LEADTIME ITEM FOR E4448A-HB2 |
ATP06 | ATP LEADTIME ITEM FOR E4448A-HGT |
ATP07 | ATP LEADTIME ITEM FOR E4448A-HN9 |
ATP08 | ATP LEADTIME ITEM FOR E4448A-JMP |
AYZ | External mixing |
B78 | CDMA2000 Measurement Personality |
B7J | Digital Demodulation Hardware |
BAB | 3.5 mm RF input connector |
BAC | CDMAOne Measurement Personality |
BAE | NADC,PDC Measurement Personality |
BAF | W-CDMA Measurement Personality |
C01 | RF connector color code |
H25 | 25 MHz IF Output |
H26 | High Band Preamplifier (Discontiued) Replaced by option 110. |
H70 | 70 MHz IF Output |
H7L | Auxiliary Wideband Log Video Output |
HB2 | 21.4 MHz IF Output |
HB6 | Prevention of unauthorized FW upgrade |
HBA | Rear Panel RF Input |
HGT | Allows Gate width of less than 10 uSec. |
HN8 | Wideband Preselector Bypass (No Preselector) |
HN9 | 80 MHz wide baseband IF output at 321.4 MHz for frequencies less than 3.05 GHz |
HNQ | I/Q Front Panel Output connectors with hardware for use with 89600A. |
HS1 | Increase level of security write protects to user files |
HS7 | Security erase software |
HT1 | GPS Interface Card for Trimble GPS |
HV5 | Y-AXIS VIDEO OUTPUT modified to 856x output level |
HY3 | Combine Option 123 and AYZ |
HY7 | Improved Gain 70 MHz IF Output |
HYX | 21.4 MHz IF Rear Panel Output |
JMP | Rear panel jumper cable |
N6171A | MATLAB Software |
N6171A-M01 | MATLAB - Basic Package |
N6171A-M02 | MATLAB - Standard Package |
N6171A-M03 | MATLAB - Advanced Package |
N9051A | Pulse measurement software |
N9051A-2FP | Pulse measurement software, fixed, perpetual, license |
N9051A-3FP | Phase & Frequency Measurements |
N9051A-4FP | Extended Analysis & Statistics |
PS-S20-01 | Recommended Startup assistance |
R-50C-001 | Standard Calibration w/data. Replaced UK6 |
R-50C-002 | Traceable Calibration standards compliant initial receipt. (ANSI-Z540/17025) |
R-50C-011-3 | Agilent Calibration - 3 years |
R-50C-011-5 | Agilent Calibration - 5 years |
R-50C-016-3 | ISO 17025 Compliant Calibration - 3 years |
R-50C-016-5 | ISO 17025 Compliant Calibration - 5 years |
R-50C-021-3 | ANSI Z540-1-1994 Calibration - 3 years |
R-50C-021-5 | ANSI Z540-1-1994 Calibration - 5 years |
R-50G-521 | Z540 CALIBRATION |
R-51B-001-3C | Return to Agilent Warranty - 3 years |
R-51B-001-5C | Return to Agilent Warranty - 5 years |
R-51B-001-C | Return to Agilent Warranty - 1 year |
R-52A-001-3 | 3 Year Calibration License (Commercial) |
R-52A-001-L | Lifetime Calibration License (Commercial) |
R-52A-002-3 | 3 Year Calibration License (Z540/17025) |
R-52A-002-L | Lifetime Calibration License (Z540/17025) |
RMKT | Agilent Refurbished Product (Do Not Use - Certiprime Option) |
UE2 | Firmware Kit. CD-ROM. |
UK6 | Commercial Cal Certificate with Data |
FAQ:
1.Can you ship order to Canada or Australia?
Yes,we can .We send orders worldwide.
2. What delivery method do you use? and delivery time?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question?
You can contact us online or leave us messages below.